FEB_1117    15.03.24 09:33:31

TextEdit.txt
            09:33:31:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
09:33:31:ST3_Shared:INFO:	                       FEB-Microcable                       
09:33:31:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
09:33:31:febtest:INFO:	Testing FEB with SN 1117
09:33:34:smx_tester:INFO:	Scanning setup
09:33:34:elinks:INFO:	Disabling clock on downlink 0
09:33:34:elinks:INFO:	Disabling clock on downlink 1
09:33:34:elinks:INFO:	Disabling clock on downlink 2
09:33:34:elinks:INFO:	Disabling clock on downlink 3
09:33:34:elinks:INFO:	Disabling clock on downlink 4
09:33:34:setup_element:INFO:	Checking SOS, encoding_mode: SOS
09:33:34:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
09:33:34:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
09:33:34:elinks:INFO:	Disabling clock on downlink 0
09:33:34:elinks:INFO:	Disabling clock on downlink 1
09:33:34:elinks:INFO:	Disabling clock on downlink 2
09:33:34:elinks:INFO:	Disabling clock on downlink 3
09:33:34:elinks:INFO:	Disabling clock on downlink 4
09:33:34:setup_element:INFO:	Checking SOS, encoding_mode: SOS
09:33:34:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
09:33:34:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
09:33:34:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
09:33:34:elinks:INFO:	Disabling clock on downlink 0
09:33:34:elinks:INFO:	Disabling clock on downlink 1
09:33:34:elinks:INFO:	Disabling clock on downlink 2
09:33:34:elinks:INFO:	Disabling clock on downlink 3
09:33:34:elinks:INFO:	Disabling clock on downlink 4
09:33:34:setup_element:INFO:	Checking SOS, encoding_mode: SOS
09:33:34:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
09:33:34:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
09:33:34:elinks:INFO:	Disabling clock on downlink 0
09:33:34:elinks:INFO:	Disabling clock on downlink 1
09:33:34:elinks:INFO:	Disabling clock on downlink 2
09:33:34:elinks:INFO:	Disabling clock on downlink 3
09:33:34:elinks:INFO:	Disabling clock on downlink 4
09:33:34:setup_element:INFO:	Checking SOS, encoding_mode: SOS
09:33:34:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
09:33:34:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
09:33:34:elinks:INFO:	Disabling clock on downlink 0
09:33:34:elinks:INFO:	Disabling clock on downlink 1
09:33:35:elinks:INFO:	Disabling clock on downlink 2
09:33:35:elinks:INFO:	Disabling clock on downlink 3
09:33:35:elinks:INFO:	Disabling clock on downlink 4
09:33:35:setup_element:INFO:	Checking SOS, encoding_mode: SOS
09:33:35:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
09:33:35:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
09:33:35:setup_element:INFO:	Scanning clock phase
09:33:35:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
09:33:35:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
09:33:35:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
09:33:35:setup_element:INFO:	Eye window for uplink 8 : ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 9 : ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 10: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 11: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 12: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 13: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
09:33:35:setup_element:INFO:	Eye window for uplink 14: ________________________________________________________________________XXXXXX__
Clock Delay: 34
09:33:35:setup_element:INFO:	Eye window for uplink 15: ________________________________________________________________________XXXXXX__
Clock Delay: 34
09:33:35:setup_element:INFO:	Setting the clock phase to 33 for group 0, downlink 1
09:33:35:setup_element:INFO:	Scanning data phases
09:33:35:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
09:33:35:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
09:33:40:setup_element:INFO:	Data phase scan results for group 0, downlink 1
09:33:40:setup_element:INFO:	Eye window for uplink 8 : ______________________________XXXX______
Data delay found: 11
09:33:40:setup_element:INFO:	Eye window for uplink 9 : ___________________________________XXXXX
Data delay found: 17
09:33:40:setup_element:INFO:	Eye window for uplink 10: ________________________________XXXXX___
Data delay found: 14
09:33:40:setup_element:INFO:	Eye window for uplink 11: XX__________________________________XXXX
Data delay found: 18
09:33:40:setup_element:INFO:	Eye window for uplink 12: _______________________________XXXXX____
Data delay found: 13
09:33:40:setup_element:INFO:	Eye window for uplink 13: __________________________________XXXXX_
Data delay found: 16
09:33:40:setup_element:INFO:	Eye window for uplink 14: X____________________________________XXX
Data delay found: 18
09:33:40:setup_element:INFO:	Eye window for uplink 15: XXX__________________________________XXX
Data delay found: 19
09:33:40:setup_element:INFO:	Setting the data phase to 11 for uplink 8
09:33:40:setup_element:INFO:	Setting the data phase to 17 for uplink 9
09:33:40:setup_element:INFO:	Setting the data phase to 14 for uplink 10
09:33:40:setup_element:INFO:	Setting the data phase to 18 for uplink 11
09:33:40:setup_element:INFO:	Setting the data phase to 13 for uplink 12
09:33:40:setup_element:INFO:	Setting the data phase to 16 for uplink 13
09:33:40:setup_element:INFO:	Setting the data phase to 18 for uplink 14
09:33:40:setup_element:INFO:	Setting the data phase to 19 for uplink 15
09:33:40:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 72
    Eye Windows:
      Uplink  8: ______________________________________________________________________XXXXXXXX__
      Uplink  9: ______________________________________________________________________XXXXXXXX__
      Uplink 10: ______________________________________________________________________XXXXXXXX__
      Uplink 11: ______________________________________________________________________XXXXXXXX__
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ________________________________________________________________________XXXXXX__
      Uplink 15: ________________________________________________________________________XXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 11
      Window Length: 36
      Eye Window: ______________________________XXXX______
    Uplink 9:
      Optimal Phase: 17
      Window Length: 35
      Eye Window: ___________________________________XXXXX
    Uplink 10:
      Optimal Phase: 14
      Window Length: 35
      Eye Window: ________________________________XXXXX___
    Uplink 11:
      Optimal Phase: 18
      Window Length: 34
      Eye Window: XX__________________________________XXXX
    Uplink 12:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 13:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_
    Uplink 14:
      Optimal Phase: 18
      Window Length: 36
      Eye Window: X____________________________________XXX
    Uplink 15:
      Optimal Phase: 19
      Window Length: 34
      Eye Window: XXX__________________________________XXX
]
09:33:40:setup_element:INFO:	Beginning SMX ASICs map scan
09:33:40:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
09:33:40:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
09:33:40:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
09:33:40:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
09:33:40:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
09:33:41:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
09:33:41:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
09:33:41:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
09:33:41:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
09:33:41:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
09:33:41:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
09:33:42:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
09:33:42:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
09:33:43:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 72
    Eye Windows:
      Uplink  8: ______________________________________________________________________XXXXXXXX__
      Uplink  9: ______________________________________________________________________XXXXXXXX__
      Uplink 10: ______________________________________________________________________XXXXXXXX__
      Uplink 11: ______________________________________________________________________XXXXXXXX__
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ________________________________________________________________________XXXXXX__
      Uplink 15: ________________________________________________________________________XXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 11
      Window Length: 36
      Eye Window: ______________________________XXXX______
    Uplink 9:
      Optimal Phase: 17
      Window Length: 35
      Eye Window: ___________________________________XXXXX
    Uplink 10:
      Optimal Phase: 14
      Window Length: 35
      Eye Window: ________________________________XXXXX___
    Uplink 11:
      Optimal Phase: 18
      Window Length: 34
      Eye Window: XX__________________________________XXXX
    Uplink 12:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 13:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_
    Uplink 14:
      Optimal Phase: 18
      Window Length: 36
      Eye Window: X____________________________________XXX
    Uplink 15:
      Optimal Phase: 19
      Window Length: 34
      Eye Window: XXX__________________________________XXX

09:33:43:setup_element:INFO:	Performing Elink synchronization
09:33:43:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
09:33:43:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
09:33:43:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
09:33:43:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
09:33:43:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
09:33:43:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
09:33:43:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_1_8 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_1__upli_8
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_3_10 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_3__upli_10
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
09:33:44:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
09:33:44:febtest:INFO:	08-01 | XA-000-08-002-001-007-061-07 |  18.7 | 1218.6
09:33:45:febtest:INFO:	10-03 | XA-000-08-002-001-007-057-07 |  25.1 | 1201.0
09:33:45:febtest:INFO:	12-05 | XA-000-08-002-001-007-062-07 |  21.9 | 1212.7
09:33:45:febtest:INFO:	14-07 | XA-000-08-002-001-007-053-07 |  28.2 | 1177.4
09:33:45:ST3_smx:INFO:	Configuring SMX FAST
09:33:47:ST3_smx:INFO:	chip: 8-1 	 28.225000 C 	 1177.390875 mV
09:33:47:ST3_smx:INFO:		Electrons
09:33:47:ST3_smx:INFO:	# loops 0
09:33:49:ST3_smx:INFO:	# loops 1
09:33:51:ST3_smx:INFO:	# loops 2
09:33:52:ST3_smx:INFO:	Total # of broken channels: 0
09:33:52:ST3_smx:INFO:	List of broken channels: []
09:33:52:ST3_smx:INFO:	Total # of broken channels: 0
09:33:52:ST3_smx:INFO:	List of broken channels: []
09:33:53:ST3_smx:INFO:	Configuring SMX FAST
09:33:55:ST3_smx:INFO:	chip: 10-3 	 21.902970 C 	 1206.851500 mV
09:33:55:ST3_smx:INFO:		Electrons
09:33:55:ST3_smx:INFO:	# loops 0
09:33:57:ST3_smx:INFO:	# loops 1
09:33:59:ST3_smx:INFO:	# loops 2
09:34:00:ST3_smx:INFO:	Total # of broken channels: 0
09:34:00:ST3_smx:INFO:	List of broken channels: []
09:34:00:ST3_smx:INFO:	Total # of broken channels: 0
09:34:00:ST3_smx:INFO:	List of broken channels: []
09:34:01:ST3_smx:INFO:	Configuring SMX FAST
09:34:03:ST3_smx:INFO:	chip: 12-5 	 28.225000 C 	 1183.292940 mV
09:34:03:ST3_smx:INFO:		Electrons
09:34:03:ST3_smx:INFO:	# loops 0
09:34:05:ST3_smx:INFO:	# loops 1
09:34:07:ST3_smx:INFO:	# loops 2
09:34:08:ST3_smx:INFO:	Total # of broken channels: 0
09:34:08:ST3_smx:INFO:	List of broken channels: []
09:34:08:ST3_smx:INFO:	Total # of broken channels: 0
09:34:08:ST3_smx:INFO:	List of broken channels: []
09:34:09:ST3_smx:INFO:	Configuring SMX FAST
09:34:11:ST3_smx:INFO:	chip: 14-7 	 28.225000 C 	 1189.190035 mV
09:34:11:ST3_smx:INFO:		Electrons
09:34:11:ST3_smx:INFO:	# loops 0
09:34:13:ST3_smx:INFO:	# loops 1
09:34:15:ST3_smx:INFO:	# loops 2
09:34:16:ST3_smx:INFO:	Total # of broken channels: 0
09:34:16:ST3_smx:INFO:	List of broken channels: []
09:34:16:ST3_smx:INFO:	Total # of broken channels: 0
09:34:16:ST3_smx:INFO:	List of broken channels: []
09:34:17:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
09:34:18:febtest:INFO:	08-01 | XA-000-08-002-001-007-061-07 |  28.2 | 1177.4
09:34:18:febtest:INFO:	10-03 | XA-000-08-002-001-007-057-07 |  21.9 | 1206.9
09:34:18:febtest:INFO:	12-05 | XA-000-08-002-001-007-062-07 |  31.4 | 1183.3
09:34:18:febtest:INFO:	14-07 | XA-000-08-002-001-007-053-07 |  28.2 | 1189.2
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_03_15-09_33_31
OPERATOR  : Oleksandr S.; 
SITE      : GSI
SETUP     : GSI_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : L5DL100116 M5DL1T0001160A2 42 A

FEB_SN : 1117
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.450', '0.9000', '1.850', '1.3520', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '0.9952', '1.850', '0.4430', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '0.9903', '1.850', '0.1611', '0.000', '0.0000', '0.000', '0.0000']