FEB_1143    04.04.24 13:40:58

TextEdit.txt
            13:40:58:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
13:40:58:ST3_Shared:INFO:	                       FEB-Microcable                       
13:40:58:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
13:40:59:febtest:INFO:	Testing FEB with SN 1143
13:41:02:smx_tester:INFO:	Scanning setup
13:41:02:elinks:INFO:	Disabling clock on downlink 0
13:41:02:elinks:INFO:	Disabling clock on downlink 1
13:41:02:elinks:INFO:	Disabling clock on downlink 2
13:41:02:elinks:INFO:	Disabling clock on downlink 3
13:41:02:elinks:INFO:	Disabling clock on downlink 4
13:41:02:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:41:02:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
13:41:02:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:41:02:elinks:INFO:	Disabling clock on downlink 0
13:41:02:elinks:INFO:	Disabling clock on downlink 1
13:41:02:elinks:INFO:	Disabling clock on downlink 2
13:41:02:elinks:INFO:	Disabling clock on downlink 3
13:41:02:elinks:INFO:	Disabling clock on downlink 4
13:41:02:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:41:02:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
13:41:02:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
13:41:02:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:41:02:elinks:INFO:	Disabling clock on downlink 0
13:41:02:elinks:INFO:	Disabling clock on downlink 1
13:41:02:elinks:INFO:	Disabling clock on downlink 2
13:41:02:elinks:INFO:	Disabling clock on downlink 3
13:41:02:elinks:INFO:	Disabling clock on downlink 4
13:41:02:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:41:02:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
13:41:02:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:41:02:elinks:INFO:	Disabling clock on downlink 0
13:41:02:elinks:INFO:	Disabling clock on downlink 1
13:41:02:elinks:INFO:	Disabling clock on downlink 2
13:41:02:elinks:INFO:	Disabling clock on downlink 3
13:41:02:elinks:INFO:	Disabling clock on downlink 4
13:41:02:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:41:02:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
13:41:02:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:41:02:elinks:INFO:	Disabling clock on downlink 0
13:41:02:elinks:INFO:	Disabling clock on downlink 1
13:41:02:elinks:INFO:	Disabling clock on downlink 2
13:41:02:elinks:INFO:	Disabling clock on downlink 3
13:41:02:elinks:INFO:	Disabling clock on downlink 4
13:41:02:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:41:02:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
13:41:02:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:41:03:setup_element:INFO:	Scanning clock phase
13:41:03:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:41:03:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:41:03:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
13:41:03:setup_element:INFO:	Eye window for uplink 8 : _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
13:41:03:setup_element:INFO:	Eye window for uplink 9 : _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
13:41:03:setup_element:INFO:	Eye window for uplink 10: ________________________________________________________________________________
Clock Delay: 40
13:41:03:setup_element:INFO:	Eye window for uplink 11: ________________________________________________________________________________
Clock Delay: 40
13:41:03:setup_element:INFO:	Eye window for uplink 12: ________________________________________________________________________________
Clock Delay: 40
13:41:03:setup_element:INFO:	Eye window for uplink 13: ________________________________________________________________________________
Clock Delay: 40
13:41:03:setup_element:INFO:	Eye window for uplink 14: _______________________________________________________________________XXXXXXX__
Clock Delay: 34
13:41:03:setup_element:INFO:	Eye window for uplink 15: _______________________________________________________________________XXXXXXX__
Clock Delay: 34
13:41:03:setup_element:INFO:	Setting the clock phase to 33 for group 0, downlink 1
13:41:03:setup_element:INFO:	Scanning data phases
13:41:03:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:41:03:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:41:08:setup_element:INFO:	Data phase scan results for group 0, downlink 1
13:41:08:setup_element:INFO:	Eye window for uplink 8 : _____________________________XXXX_______
Data delay found: 10
13:41:08:setup_element:INFO:	Eye window for uplink 9 : _________________________________XXXXXX_
Data delay found: 15
13:41:08:setup_element:INFO:	Eye window for uplink 10: ______________________________XXXXXXXXXX
Data delay found: 14
13:41:08:setup_element:INFO:	Eye window for uplink 11: ________________________________XXXXXXXX
Data delay found: 15
13:41:08:setup_element:INFO:	Eye window for uplink 12: _________________________________XXXX___
Data delay found: 14
13:41:08:setup_element:INFO:	Eye window for uplink 13: ____________________________________XXXX
Data delay found: 17
13:41:08:setup_element:INFO:	Eye window for uplink 14: _______________________________XXXXX____
Data delay found: 13
13:41:08:setup_element:INFO:	Eye window for uplink 15: ________________________________XXXXXX__
Data delay found: 14
13:41:08:setup_element:INFO:	Setting the data phase to 10 for uplink 8
13:41:08:setup_element:INFO:	Setting the data phase to 15 for uplink 9
13:41:08:setup_element:INFO:	Setting the data phase to 14 for uplink 10
13:41:08:setup_element:INFO:	Setting the data phase to 15 for uplink 11
13:41:08:setup_element:INFO:	Setting the data phase to 14 for uplink 12
13:41:08:setup_element:INFO:	Setting the data phase to 17 for uplink 13
13:41:08:setup_element:INFO:	Setting the data phase to 13 for uplink 14
13:41:08:setup_element:INFO:	Setting the data phase to 14 for uplink 15
13:41:08:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 71
    Eye Windows:
      Uplink  8: _____________________________________________________________________XXXXXXXX___
      Uplink  9: _____________________________________________________________________XXXXXXXX___
      Uplink 10: ________________________________________________________________________________
      Uplink 11: ________________________________________________________________________________
      Uplink 12: ________________________________________________________________________________
      Uplink 13: ________________________________________________________________________________
      Uplink 14: _______________________________________________________________________XXXXXXX__
      Uplink 15: _______________________________________________________________________XXXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 9:
      Optimal Phase: 15
      Window Length: 34
      Eye Window: _________________________________XXXXXX_
    Uplink 10:
      Optimal Phase: 14
      Window Length: 30
      Eye Window: ______________________________XXXXXXXXXX
    Uplink 11:
      Optimal Phase: 15
      Window Length: 32
      Eye Window: ________________________________XXXXXXXX
    Uplink 12:
      Optimal Phase: 14
      Window Length: 36
      Eye Window: _________________________________XXXX___
    Uplink 13:
      Optimal Phase: 17
      Window Length: 36
      Eye Window: ____________________________________XXXX
    Uplink 14:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 15:
      Optimal Phase: 14
      Window Length: 34
      Eye Window: ________________________________XXXXXX__
]
13:41:08:setup_element:INFO:	Beginning SMX ASICs map scan
13:41:08:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:41:08:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:41:08:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
13:41:08:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
13:41:08:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
13:41:08:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
13:41:09:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
13:41:09:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
13:41:09:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
13:41:09:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
13:41:09:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
13:41:10:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
13:41:10:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
13:41:11:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 71
    Eye Windows:
      Uplink  8: _____________________________________________________________________XXXXXXXX___
      Uplink  9: _____________________________________________________________________XXXXXXXX___
      Uplink 10: ________________________________________________________________________________
      Uplink 11: ________________________________________________________________________________
      Uplink 12: ________________________________________________________________________________
      Uplink 13: ________________________________________________________________________________
      Uplink 14: _______________________________________________________________________XXXXXXX__
      Uplink 15: _______________________________________________________________________XXXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 9:
      Optimal Phase: 15
      Window Length: 34
      Eye Window: _________________________________XXXXXX_
    Uplink 10:
      Optimal Phase: 14
      Window Length: 30
      Eye Window: ______________________________XXXXXXXXXX
    Uplink 11:
      Optimal Phase: 15
      Window Length: 32
      Eye Window: ________________________________XXXXXXXX
    Uplink 12:
      Optimal Phase: 14
      Window Length: 36
      Eye Window: _________________________________XXXX___
    Uplink 13:
      Optimal Phase: 17
      Window Length: 36
      Eye Window: ____________________________________XXXX
    Uplink 14:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 15:
      Optimal Phase: 14
      Window Length: 34
      Eye Window: ________________________________XXXXXX__

13:41:11:setup_element:INFO:	Performing Elink synchronization
13:41:11:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:41:11:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:41:11:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
13:41:11:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
13:41:11:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
13:41:11:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
13:41:11:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
13:41:12:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
13:41:12:febtest:INFO:	08-01 | XA-000-08-002-000-006-078-14 |  47.3 | 1153.7
13:41:12:febtest:INFO:	10-03 | XA-000-08-002-000-006-077-14 |  47.3 | 1153.7
13:41:13:febtest:INFO:	12-05 | XA-000-08-002-000-006-076-14 |  25.1 | 1236.2
13:41:13:febtest:INFO:	14-07 | XA-000-08-002-000-006-079-14 |  44.1 | 1177.4
13:41:13:ST3_smx:INFO:	Configuring SMX FAST
13:41:15:ST3_smx:INFO:	chip: 8-1 	 47.250730 C 	 1153.732915 mV
13:41:15:ST3_smx:INFO:		Electrons
13:41:15:ST3_smx:INFO:	# loops 0
13:41:17:ST3_smx:INFO:	# loops 1
13:41:18:ST3_smx:INFO:	# loops 2
13:41:20:ST3_smx:INFO:	Total # of broken channels: 0
13:41:20:ST3_smx:INFO:	List of broken channels: []
13:41:20:ST3_smx:INFO:	Total # of broken channels: 0
13:41:20:ST3_smx:INFO:	List of broken channels: []
13:41:21:ST3_smx:INFO:	Configuring SMX FAST
13:41:23:ST3_smx:INFO:	chip: 10-3 	 47.250730 C 	 1153.732915 mV
13:41:23:ST3_smx:INFO:		Electrons
13:41:23:ST3_smx:INFO:	# loops 0
13:41:25:ST3_smx:INFO:	# loops 1
13:41:26:ST3_smx:INFO:	# loops 2
13:41:28:ST3_smx:INFO:	Total # of broken channels: 0
13:41:28:ST3_smx:INFO:	List of broken channels: []
13:41:28:ST3_smx:INFO:	Total # of broken channels: 0
13:41:28:ST3_smx:INFO:	List of broken channels: []
13:41:29:ST3_smx:INFO:	Configuring SMX FAST
13:41:31:ST3_smx:INFO:	chip: 12-5 	 28.225000 C 	 1224.468235 mV
13:41:31:ST3_smx:INFO:		Electrons
13:41:31:ST3_smx:INFO:	# loops 0
13:41:33:ST3_smx:INFO:	# loops 1
13:41:34:ST3_smx:INFO:	# loops 2
13:41:36:ST3_smx:INFO:	Total # of broken channels: 0
13:41:36:ST3_smx:INFO:	List of broken channels: []
13:41:36:ST3_smx:INFO:	Total # of broken channels: 0
13:41:36:ST3_smx:INFO:	List of broken channels: []
13:41:37:ST3_smx:INFO:	Configuring SMX FAST
13:41:39:ST3_smx:INFO:	chip: 14-7 	 44.073563 C 	 1183.292940 mV
13:41:39:ST3_smx:INFO:		Electrons
13:41:39:ST3_smx:INFO:	# loops 0
13:41:41:ST3_smx:INFO:	# loops 1
13:41:42:ST3_smx:INFO:	# loops 2
13:41:44:ST3_smx:INFO:	Total # of broken channels: 0
13:41:44:ST3_smx:INFO:	List of broken channels: []
13:41:44:ST3_smx:INFO:	Total # of broken channels: 0
13:41:44:ST3_smx:INFO:	List of broken channels: []
13:41:45:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
13:41:45:febtest:INFO:	08-01 | XA-000-08-002-000-006-078-14 |  47.3 | 1159.7
13:41:45:febtest:INFO:	10-03 | XA-000-08-002-000-006-077-14 |  50.4 | 1153.7
13:41:46:febtest:INFO:	12-05 | XA-000-08-002-000-006-076-14 |  28.2 | 1224.5
13:41:46:febtest:INFO:	14-07 | XA-000-08-002-000-006-079-14 |  44.1 | 1189.2
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_04_04-13_40_58
OPERATOR  : Oleksandr S.; 
SITE      : GSI
SETUP     : GSI_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : 
FEB_SN : 1143
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.450', '0.7896', '1.850', '1.3540', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '1.0060', '1.850', '0.2782', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '1.0010', '1.850', '0.1647', '0.000', '0.0000', '0.000', '0.0000']