FEB_1154    15.05.24 08:25:19

TextEdit.txt
            08:25:19:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
08:25:19:ST3_Shared:INFO:	                       FEB-Microcable                       
08:25:19:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
08:25:20:febtest:INFO:	Testing FEB with SN 1154
08:25:22:smx_tester:INFO:	Scanning setup
08:25:22:elinks:INFO:	Disabling clock on downlink 0
08:25:22:elinks:INFO:	Disabling clock on downlink 1
08:25:22:elinks:INFO:	Disabling clock on downlink 2
08:25:22:elinks:INFO:	Disabling clock on downlink 3
08:25:22:elinks:INFO:	Disabling clock on downlink 4
08:25:22:setup_element:INFO:	Checking SOS, encoding_mode: SOS
08:25:22:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
08:25:22:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
08:25:22:elinks:INFO:	Disabling clock on downlink 0
08:25:22:elinks:INFO:	Disabling clock on downlink 1
08:25:22:elinks:INFO:	Disabling clock on downlink 2
08:25:22:elinks:INFO:	Disabling clock on downlink 3
08:25:22:elinks:INFO:	Disabling clock on downlink 4
08:25:22:setup_element:INFO:	Checking SOS, encoding_mode: SOS
08:25:22:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
08:25:22:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
08:25:22:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
08:25:23:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
08:25:23:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
08:25:23:elinks:INFO:	Disabling clock on downlink 0
08:25:23:elinks:INFO:	Disabling clock on downlink 1
08:25:23:elinks:INFO:	Disabling clock on downlink 2
08:25:23:elinks:INFO:	Disabling clock on downlink 3
08:25:23:elinks:INFO:	Disabling clock on downlink 4
08:25:23:setup_element:INFO:	Checking SOS, encoding_mode: SOS
08:25:23:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
08:25:23:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
08:25:23:elinks:INFO:	Disabling clock on downlink 0
08:25:23:elinks:INFO:	Disabling clock on downlink 1
08:25:23:elinks:INFO:	Disabling clock on downlink 2
08:25:23:elinks:INFO:	Disabling clock on downlink 3
08:25:23:elinks:INFO:	Disabling clock on downlink 4
08:25:23:setup_element:INFO:	Checking SOS, encoding_mode: SOS
08:25:23:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
08:25:23:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
08:25:23:elinks:INFO:	Disabling clock on downlink 0
08:25:23:elinks:INFO:	Disabling clock on downlink 1
08:25:23:elinks:INFO:	Disabling clock on downlink 2
08:25:23:elinks:INFO:	Disabling clock on downlink 3
08:25:23:elinks:INFO:	Disabling clock on downlink 4
08:25:23:setup_element:INFO:	Checking SOS, encoding_mode: SOS
08:25:23:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
08:25:23:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
08:25:23:setup_element:INFO:	Scanning clock phase
08:25:23:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
08:25:23:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:25:23:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
08:25:23:setup_element:INFO:	Eye window for uplink 8 : _____________________________________________________________________XXXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Eye window for uplink 9 : _____________________________________________________________________XXXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Eye window for uplink 10: _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:25:23:setup_element:INFO:	Eye window for uplink 11: _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:25:23:setup_element:INFO:	Eye window for uplink 12: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Eye window for uplink 13: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Eye window for uplink 14: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Eye window for uplink 15: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
08:25:23:setup_element:INFO:	Setting the clock phase to 33 for group 0, downlink 1
08:25:23:setup_element:INFO:	Scanning data phases
08:25:23:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
08:25:23:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:25:28:setup_element:INFO:	Data phase scan results for group 0, downlink 1
08:25:28:setup_element:INFO:	Eye window for uplink 8 : _____________________________XXXX_______
Data delay found: 10
08:25:28:setup_element:INFO:	Eye window for uplink 9 : _________________________________XXXXX__
Data delay found: 15
08:25:28:setup_element:INFO:	Eye window for uplink 10: _______________________________XXXX_____
Data delay found: 12
08:25:28:setup_element:INFO:	Eye window for uplink 11: __________________________________XXXXXX
Data delay found: 16
08:25:28:setup_element:INFO:	Eye window for uplink 12: _________________________________XXXXX__
Data delay found: 15
08:25:28:setup_element:INFO:	Eye window for uplink 13: X___________________________________XXXX
Data delay found: 18
08:25:28:setup_element:INFO:	Eye window for uplink 14: _______________________________XXXXX____
Data delay found: 13
08:25:28:setup_element:INFO:	Eye window for uplink 15: _________________________________XXXXX__
Data delay found: 15
08:25:28:setup_element:INFO:	Setting the data phase to 10 for uplink 8
08:25:28:setup_element:INFO:	Setting the data phase to 15 for uplink 9
08:25:28:setup_element:INFO:	Setting the data phase to 12 for uplink 10
08:25:28:setup_element:INFO:	Setting the data phase to 16 for uplink 11
08:25:28:setup_element:INFO:	Setting the data phase to 15 for uplink 12
08:25:28:setup_element:INFO:	Setting the data phase to 18 for uplink 13
08:25:28:setup_element:INFO:	Setting the data phase to 13 for uplink 14
08:25:28:setup_element:INFO:	Setting the data phase to 15 for uplink 15
08:25:28:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 71
    Eye Windows:
      Uplink  8: _____________________________________________________________________XXXXXXXXX__
      Uplink  9: _____________________________________________________________________XXXXXXXXX__
      Uplink 10: _____________________________________________________________________XXXXXXXX___
      Uplink 11: _____________________________________________________________________XXXXXXXX___
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ______________________________________________________________________XXXXXXXX__
      Uplink 15: ______________________________________________________________________XXXXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 9:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 10:
      Optimal Phase: 12
      Window Length: 36
      Eye Window: _______________________________XXXX_____
    Uplink 11:
      Optimal Phase: 16
      Window Length: 34
      Eye Window: __________________________________XXXXXX
    Uplink 12:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 13:
      Optimal Phase: 18
      Window Length: 35
      Eye Window: X___________________________________XXXX
    Uplink 14:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 15:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
]
08:25:28:setup_element:INFO:	Beginning SMX ASICs map scan
08:25:28:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
08:25:28:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:25:28:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
08:25:28:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
08:25:28:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
08:25:28:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
08:25:28:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
08:25:29:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
08:25:29:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
08:25:29:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
08:25:29:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
08:25:29:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
08:25:29:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
08:25:31:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 33
    Window Length: 71
    Eye Windows:
      Uplink  8: _____________________________________________________________________XXXXXXXXX__
      Uplink  9: _____________________________________________________________________XXXXXXXXX__
      Uplink 10: _____________________________________________________________________XXXXXXXX___
      Uplink 11: _____________________________________________________________________XXXXXXXX___
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ______________________________________________________________________XXXXXXXX__
      Uplink 15: ______________________________________________________________________XXXXXXXX__
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 9:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 10:
      Optimal Phase: 12
      Window Length: 36
      Eye Window: _______________________________XXXX_____
    Uplink 11:
      Optimal Phase: 16
      Window Length: 34
      Eye Window: __________________________________XXXXXX
    Uplink 12:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 13:
      Optimal Phase: 18
      Window Length: 35
      Eye Window: X___________________________________XXXX
    Uplink 14:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 15:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__

08:25:31:setup_element:INFO:	Performing Elink synchronization
08:25:31:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
08:25:31:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:25:31:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
08:25:31:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
08:25:31:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
08:25:31:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
08:25:31:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_1_8 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_1__upli_8
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_3_10 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_3__upli_10
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
08:25:32:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
08:25:32:febtest:INFO:	08-01 | XA-000-08-002-002-008-007-11 |  37.7 | 1183.3
08:25:32:febtest:INFO:	10-03 | XA-000-08-002-002-008-008-11 |  25.1 | 1230.3
08:25:32:febtest:INFO:	12-05 | XA-000-08-002-002-008-193-04 |  31.4 | 1212.7
08:25:32:febtest:INFO:	14-07 | XA-000-08-002-002-008-191-08 |  15.6 | 1259.6
08:25:32:febtest:INFO:	Init all SMX (CSA): 30
08:25:40:febtest:INFO:	Set all CSA to ZERO
08:25:40:febtest:INFO:	['2.450', '1.0250', '1.850', '1.3120', '0.000', '0.0000', '0.000', '0.0000']
08:25:41:ST3_smx:INFO:	chip: 8-1 	 34.556970 C 	 1165.571835 mV
08:25:41:ST3_smx:INFO:		Electrons
08:25:41:ST3_smx:INFO:	# loops 0
08:25:43:ST3_smx:INFO:	# loops 1
08:25:45:ST3_smx:INFO:	# loops 2
08:25:46:ST3_smx:INFO:	Total # of broken channels: 0
08:25:46:ST3_smx:INFO:	List of broken channels: []
08:25:46:ST3_smx:INFO:	Total # of broken channels: 1
08:25:46:ST3_smx:INFO:	List of broken channels: [101]
08:25:48:ST3_smx:INFO:	chip: 10-3 	 28.225000 C 	 1195.082160 mV
08:25:48:ST3_smx:INFO:		Electrons
08:25:48:ST3_smx:INFO:	# loops 0
08:25:50:ST3_smx:INFO:	# loops 1
08:25:52:ST3_smx:INFO:	# loops 2
08:25:53:ST3_smx:INFO:	Total # of broken channels: 0
08:25:53:ST3_smx:INFO:	List of broken channels: []
08:25:53:ST3_smx:INFO:	Total # of broken channels: 0
08:25:53:ST3_smx:INFO:	List of broken channels: []
08:25:55:ST3_smx:INFO:	chip: 12-5 	 34.556970 C 	 1177.390875 mV
08:25:55:ST3_smx:INFO:		Electrons
08:25:55:ST3_smx:INFO:	# loops 0
08:25:57:ST3_smx:INFO:	# loops 1
08:25:59:ST3_smx:INFO:	# loops 2
08:26:00:ST3_smx:INFO:	Total # of broken channels: 0
08:26:00:ST3_smx:INFO:	List of broken channels: []
08:26:00:ST3_smx:INFO:	Total # of broken channels: 0
08:26:00:ST3_smx:INFO:	List of broken channels: []
08:26:02:ST3_smx:INFO:	chip: 14-7 	 21.902970 C 	 1212.728715 mV
08:26:02:ST3_smx:INFO:		Electrons
08:26:02:ST3_smx:INFO:	# loops 0
08:26:04:ST3_smx:INFO:	# loops 1
08:26:05:ST3_smx:INFO:	# loops 2
08:26:07:ST3_smx:INFO:	Total # of broken channels: 0
08:26:07:ST3_smx:INFO:	List of broken channels: []
08:26:07:ST3_smx:INFO:	Total # of broken channels: 1
08:26:07:ST3_smx:INFO:	List of broken channels: [16]
08:26:08:febtest:INFO:	SetCSA :30
08:26:08:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
08:26:08:febtest:INFO:	08-01 | XA-000-08-002-002-008-007-11 |  34.6 | 1153.7
08:26:08:febtest:INFO:	10-03 | XA-000-08-002-002-008-008-11 |  28.2 | 1183.3
08:26:08:febtest:INFO:	12-05 | XA-000-08-002-002-008-193-04 |  34.6 | 1165.6
08:26:08:febtest:INFO:	14-07 | XA-000-08-002-002-008-191-08 |  25.1 | 1201.0
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_05_15-08_25_19
OPERATOR  : Oleksandr S.; 
SITE      : GSI
SETUP     : GSI_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : L6DL400120 M6DL4B4001204B2 124 D

FEB_SN : 1154
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.451', '1.0100', '1.849', '1.1590', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '1.0110', '1.850', '1.1100', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '1.0290', '1.850', '1.3120', '0.000', '0.0000', '0.000', '0.0000']