FEB_1157    30.04.24 13:03:50

TextEdit.txt
            13:03:50:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
13:03:50:ST3_Shared:INFO:	                       FEB-Microcable                       
13:03:50:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
13:03:51:febtest:INFO:	Testing FEB with SN 1157
13:03:54:smx_tester:INFO:	Scanning setup
13:03:54:elinks:INFO:	Disabling clock on downlink 0
13:03:54:elinks:INFO:	Disabling clock on downlink 1
13:03:54:elinks:INFO:	Disabling clock on downlink 2
13:03:54:elinks:INFO:	Disabling clock on downlink 3
13:03:54:elinks:INFO:	Disabling clock on downlink 4
13:03:54:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
13:03:54:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:03:54:elinks:INFO:	Disabling clock on downlink 0
13:03:54:elinks:INFO:	Disabling clock on downlink 1
13:03:54:elinks:INFO:	Disabling clock on downlink 2
13:03:54:elinks:INFO:	Disabling clock on downlink 3
13:03:54:elinks:INFO:	Disabling clock on downlink 4
13:03:54:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
13:03:54:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
13:03:54:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:03:54:elinks:INFO:	Disabling clock on downlink 0
13:03:54:elinks:INFO:	Disabling clock on downlink 1
13:03:54:elinks:INFO:	Disabling clock on downlink 2
13:03:54:elinks:INFO:	Disabling clock on downlink 3
13:03:54:elinks:INFO:	Disabling clock on downlink 4
13:03:54:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
13:03:54:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:03:54:elinks:INFO:	Disabling clock on downlink 0
13:03:54:elinks:INFO:	Disabling clock on downlink 1
13:03:54:elinks:INFO:	Disabling clock on downlink 2
13:03:54:elinks:INFO:	Disabling clock on downlink 3
13:03:54:elinks:INFO:	Disabling clock on downlink 4
13:03:54:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
13:03:54:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:03:54:elinks:INFO:	Disabling clock on downlink 0
13:03:54:elinks:INFO:	Disabling clock on downlink 1
13:03:54:elinks:INFO:	Disabling clock on downlink 2
13:03:54:elinks:INFO:	Disabling clock on downlink 3
13:03:54:elinks:INFO:	Disabling clock on downlink 4
13:03:54:setup_element:INFO:	Checking SOS, encoding_mode: SOS
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
13:03:54:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
13:03:54:setup_element:INFO:	Scanning clock phase
13:03:54:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:03:55:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:03:55:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
13:03:55:setup_element:INFO:	Eye window for uplink 8 : ____________________________________________________________________XXXXXXXX____
Clock Delay: 31
13:03:55:setup_element:INFO:	Eye window for uplink 9 : ____________________________________________________________________XXXXXXXX____
Clock Delay: 31
13:03:55:setup_element:INFO:	Eye window for uplink 10: _____________________________________________________________________XXXXXXX____
Clock Delay: 32
13:03:55:setup_element:INFO:	Eye window for uplink 11: _____________________________________________________________________XXXXXXX____
Clock Delay: 32
13:03:55:setup_element:INFO:	Eye window for uplink 12: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
13:03:55:setup_element:INFO:	Eye window for uplink 13: ______________________________________________________________________XXXXXXXX__
Clock Delay: 33
13:03:55:setup_element:INFO:	Eye window for uplink 14: ______________________________________________________________________XXXXXXX___
Clock Delay: 33
13:03:55:setup_element:INFO:	Eye window for uplink 15: ______________________________________________________________________XXXXXXX___
Clock Delay: 33
13:03:55:setup_element:INFO:	Setting the clock phase to 32 for group 0, downlink 1
13:03:55:setup_element:INFO:	Scanning data phases
13:03:55:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:03:55:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:04:00:setup_element:INFO:	Data phase scan results for group 0, downlink 1
13:04:00:setup_element:INFO:	Eye window for uplink 8 : ____________________________XXXXX_______
Data delay found: 10
13:04:00:setup_element:INFO:	Eye window for uplink 9 : _________________________________XXXX___
Data delay found: 14
13:04:00:setup_element:INFO:	Eye window for uplink 10: ______________________________XXXXX_____
Data delay found: 12
13:04:00:setup_element:INFO:	Eye window for uplink 11: __________________________________XXXX__
Data delay found: 15
13:04:00:setup_element:INFO:	Eye window for uplink 12: _______________________________XXXXX____
Data delay found: 13
13:04:00:setup_element:INFO:	Eye window for uplink 13: __________________________________XXXXX_
Data delay found: 16
13:04:00:setup_element:INFO:	Eye window for uplink 14: ________________________________XXXX____
Data delay found: 13
13:04:00:setup_element:INFO:	Eye window for uplink 15: __________________________________XXXXX_
Data delay found: 16
13:04:00:setup_element:INFO:	Setting the data phase to 10 for uplink 8
13:04:00:setup_element:INFO:	Setting the data phase to 14 for uplink 9
13:04:00:setup_element:INFO:	Setting the data phase to 12 for uplink 10
13:04:00:setup_element:INFO:	Setting the data phase to 15 for uplink 11
13:04:00:setup_element:INFO:	Setting the data phase to 13 for uplink 12
13:04:00:setup_element:INFO:	Setting the data phase to 16 for uplink 13
13:04:00:setup_element:INFO:	Setting the data phase to 13 for uplink 14
13:04:00:setup_element:INFO:	Setting the data phase to 16 for uplink 15
13:04:00:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 32
    Window Length: 70
    Eye Windows:
      Uplink  8: ____________________________________________________________________XXXXXXXX____
      Uplink  9: ____________________________________________________________________XXXXXXXX____
      Uplink 10: _____________________________________________________________________XXXXXXX____
      Uplink 11: _____________________________________________________________________XXXXXXX____
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ______________________________________________________________________XXXXXXX___
      Uplink 15: ______________________________________________________________________XXXXXXX___
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 9:
      Optimal Phase: 14
      Window Length: 36
      Eye Window: _________________________________XXXX___
    Uplink 10:
      Optimal Phase: 12
      Window Length: 35
      Eye Window: ______________________________XXXXX_____
    Uplink 11:
      Optimal Phase: 15
      Window Length: 36
      Eye Window: __________________________________XXXX__
    Uplink 12:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 13:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_
    Uplink 14:
      Optimal Phase: 13
      Window Length: 36
      Eye Window: ________________________________XXXX____
    Uplink 15:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_
]
13:04:00:setup_element:INFO:	Beginning SMX ASICs map scan
13:04:00:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:04:00:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:04:00:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
13:04:00:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
13:04:00:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
13:04:00:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
13:04:00:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
13:04:01:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
13:04:01:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
13:04:01:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
13:04:01:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
13:04:02:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
13:04:02:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
13:04:03:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 32
    Window Length: 70
    Eye Windows:
      Uplink  8: ____________________________________________________________________XXXXXXXX____
      Uplink  9: ____________________________________________________________________XXXXXXXX____
      Uplink 10: _____________________________________________________________________XXXXXXX____
      Uplink 11: _____________________________________________________________________XXXXXXX____
      Uplink 12: ______________________________________________________________________XXXXXXXX__
      Uplink 13: ______________________________________________________________________XXXXXXXX__
      Uplink 14: ______________________________________________________________________XXXXXXX___
      Uplink 15: ______________________________________________________________________XXXXXXX___
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 9:
      Optimal Phase: 14
      Window Length: 36
      Eye Window: _________________________________XXXX___
    Uplink 10:
      Optimal Phase: 12
      Window Length: 35
      Eye Window: ______________________________XXXXX_____
    Uplink 11:
      Optimal Phase: 15
      Window Length: 36
      Eye Window: __________________________________XXXX__
    Uplink 12:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
    Uplink 13:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_
    Uplink 14:
      Optimal Phase: 13
      Window Length: 36
      Eye Window: ________________________________XXXX____
    Uplink 15:
      Optimal Phase: 16
      Window Length: 35
      Eye Window: __________________________________XXXXX_

13:04:03:setup_element:INFO:	Performing Elink synchronization
13:04:03:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
13:04:03:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
13:04:03:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
13:04:03:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
13:04:03:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
13:04:03:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
13:04:03:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_1_8 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_1__upli_8
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_3_10 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_3__upli_10
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
13:04:04:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
13:04:04:febtest:INFO:	08-01 | XA-000-08-002-001-007-217-06 |  25.1 | 1218.6
13:04:05:febtest:INFO:	10-03 | XA-000-08-002-001-007-216-06 |  12.4 | 1271.2
13:04:05:febtest:INFO:	12-05 | XA-000-08-002-001-007-212-06 |  21.9 | 1236.2
13:04:05:febtest:INFO:	14-07 | XA-000-08-002-001-008-219-02 |  34.6 | 1183.3
13:04:05:febtest:INFO:	Init all SMX (CSA): 30
13:04:12:febtest:INFO:	Set all CSA to ZERO
13:04:13:febtest:INFO:	['2.450', '1.0250', '1.850', '1.3240', '0.000', '0.0000', '0.000', '0.0000']
13:04:14:ST3_smx:INFO:	chip: 8-1 	 34.556970 C 	 1159.654860 mV
13:04:14:ST3_smx:INFO:		Electrons
13:04:14:ST3_smx:INFO:	# loops 0
13:04:16:ST3_smx:INFO:	# loops 1
13:04:17:ST3_smx:INFO:	# loops 2
13:04:19:ST3_smx:INFO:	Total # of broken channels: 0
13:04:19:ST3_smx:INFO:	List of broken channels: []
13:04:19:ST3_smx:INFO:	Total # of broken channels: 0
13:04:19:ST3_smx:INFO:	List of broken channels: []
13:04:21:ST3_smx:INFO:	chip: 10-3 	 18.745682 C 	 1224.468235 mV
13:04:21:ST3_smx:INFO:		Electrons
13:04:21:ST3_smx:INFO:	# loops 0
13:04:22:ST3_smx:INFO:	# loops 1
13:04:24:ST3_smx:INFO:	# loops 2
13:04:25:ST3_smx:INFO:	Total # of broken channels: 0
13:04:25:ST3_smx:INFO:	List of broken channels: []
13:04:25:ST3_smx:INFO:	Total # of broken channels: 0
13:04:25:ST3_smx:INFO:	List of broken channels: []
13:04:27:ST3_smx:INFO:	chip: 12-5 	 31.389742 C 	 1177.390875 mV
13:04:27:ST3_smx:INFO:		Electrons
13:04:27:ST3_smx:INFO:	# loops 0
13:04:29:ST3_smx:INFO:	# loops 1
13:04:30:ST3_smx:INFO:	# loops 2
13:04:32:ST3_smx:INFO:	Total # of broken channels: 0
13:04:32:ST3_smx:INFO:	List of broken channels: []
13:04:32:ST3_smx:INFO:	Total # of broken channels: 0
13:04:32:ST3_smx:INFO:	List of broken channels: []
13:04:34:ST3_smx:INFO:	chip: 14-7 	 37.726682 C 	 1147.806000 mV
13:04:34:ST3_smx:INFO:		Electrons
13:04:34:ST3_smx:INFO:	# loops 0
13:04:35:ST3_smx:INFO:	# loops 1
13:04:37:ST3_smx:INFO:	# loops 2
13:04:38:ST3_smx:INFO:	Total # of broken channels: 0
13:04:38:ST3_smx:INFO:	List of broken channels: []
13:04:38:ST3_smx:INFO:	Total # of broken channels: 0
13:04:38:ST3_smx:INFO:	List of broken channels: []
13:04:39:febtest:INFO:	SetCSA :30
13:04:39:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
13:04:39:febtest:INFO:	08-01 | XA-000-08-002-001-007-217-06 |  34.6 | 1147.8
13:04:40:febtest:INFO:	10-03 | XA-000-08-002-001-007-216-06 |  18.7 | 1212.7
13:04:40:febtest:INFO:	12-05 | XA-000-08-002-001-007-212-06 |  31.4 | 1165.6
13:04:40:febtest:INFO:	14-07 | XA-000-08-002-001-008-219-02 |  40.9 | 1135.9
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_04_30-13_03_50
OPERATOR  : Oleksandr S.; 
SITE      : GSI
SETUP     : GSI_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : 
FEB_SN : 1157
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.451', '0.9196', '1.850', '1.3260', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '1.0220', '1.850', '1.1660', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '1.0230', '1.850', '1.3240', '0.000', '0.0000', '0.000', '0.0000']