FEB_1515 25.11.25 08:32:18
Info
08:32:18:ST3_Shared:INFO: oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
08:32:18:ST3_Shared:INFO: FEB-Microcable
08:32:18:ST3_Shared:INFO: oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
08:32:18:febtest:INFO: Testing FEB with SN 1515
==============================================OOO==============================================
08:32:20:smx_tester:INFO: Scanning setup
08:32:20:elinks:INFO: Disabling clock on downlink 0
08:32:20:elinks:INFO: Disabling clock on downlink 1
08:32:20:elinks:INFO: Disabling clock on downlink 2
08:32:20:elinks:INFO: Disabling clock on downlink 3
08:32:20:elinks:INFO: Disabling clock on downlink 4
08:32:20:setup_element:INFO: Checking SOS, encoding_mode: SOS
08:32:20:master:INFO: Setting encoding mode SOS for groups [0], downlinks [0]
08:32:20:setup_element:INFO: Reassigning uplinks to uplinks which passed SOS detection
08:32:20:elinks:INFO: Disabling clock on downlink 0
08:32:20:elinks:INFO: Disabling clock on downlink 1
08:32:20:elinks:INFO: Disabling clock on downlink 2
08:32:20:elinks:INFO: Disabling clock on downlink 3
08:32:20:elinks:INFO: Disabling clock on downlink 4
08:32:20:setup_element:INFO: Checking SOS, encoding_mode: SOS
08:32:20:master:INFO: Setting encoding mode SOS for groups [0], downlinks [1]
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 8
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 9
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 10
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 11
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 12
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 13
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 14
08:32:20:setup_element:INFO: SOS detected for group 0, downlink 1, uplink 15
08:32:20:setup_element:INFO: Reassigning uplinks to uplinks which passed SOS detection
08:32:20:elinks:INFO: Disabling clock on downlink 0
08:32:20:elinks:INFO: Disabling clock on downlink 1
08:32:20:elinks:INFO: Disabling clock on downlink 2
08:32:20:elinks:INFO: Disabling clock on downlink 3
08:32:20:elinks:INFO: Disabling clock on downlink 4
08:32:20:setup_element:INFO: Checking SOS, encoding_mode: SOS
08:32:20:master:INFO: Setting encoding mode SOS for groups [0], downlinks [2]
08:32:21:setup_element:INFO: Reassigning uplinks to uplinks which passed SOS detection
08:32:21:elinks:INFO: Disabling clock on downlink 0
08:32:21:elinks:INFO: Disabling clock on downlink 1
08:32:21:elinks:INFO: Disabling clock on downlink 2
08:32:21:elinks:INFO: Disabling clock on downlink 3
08:32:21:elinks:INFO: Disabling clock on downlink 4
08:32:21:setup_element:INFO: Checking SOS, encoding_mode: SOS
08:32:21:master:INFO: Setting encoding mode SOS for groups [0], downlinks [3]
08:32:21:setup_element:INFO: Reassigning uplinks to uplinks which passed SOS detection
08:32:21:elinks:INFO: Disabling clock on downlink 0
08:32:21:elinks:INFO: Disabling clock on downlink 1
08:32:21:elinks:INFO: Disabling clock on downlink 2
08:32:21:elinks:INFO: Disabling clock on downlink 3
08:32:21:elinks:INFO: Disabling clock on downlink 4
08:32:21:setup_element:INFO: Checking SOS, encoding_mode: SOS
08:32:21:master:INFO: Setting encoding mode SOS for groups [0], downlinks [4]
08:32:21:setup_element:INFO: Reassigning uplinks to uplinks which passed SOS detection
==============================================OOO==============================================
08:32:21:setup_element:INFO: Scanning clock phase
08:32:21:master:INFO: Setting encoding mode SOS for groups [0], downlinks [1]
08:32:21:master:INFO: Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:32:21:setup_element:INFO: Clock phase scan results for group 0, downlink 1
08:32:21:setup_element:INFO: Eye window for uplink 8 : _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:32:21:setup_element:INFO: Eye window for uplink 9 : _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:32:21:setup_element:INFO: Eye window for uplink 10: ____________________________________________________________________XXXXXXX_____
Clock Delay: 31
08:32:21:setup_element:INFO: Eye window for uplink 11: ____________________________________________________________________XXXXXXX_____
Clock Delay: 31
08:32:21:setup_element:INFO: Eye window for uplink 12: _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:32:21:setup_element:INFO: Eye window for uplink 13: _____________________________________________________________________XXXXXXXX___
Clock Delay: 32
08:32:21:setup_element:INFO: Eye window for uplink 14: ____________________________________________________________________XXXXXXXX____
Clock Delay: 31
08:32:21:setup_element:INFO: Eye window for uplink 15: ____________________________________________________________________XXXXXXXX____
Clock Delay: 31
08:32:21:setup_element:INFO: Setting the clock phase to 32 for group 0, downlink 1
==============================================OOO==============================================
08:32:21:setup_element:INFO: Scanning data phases
08:32:21:master:INFO: Setting encoding mode SOS for groups [0], downlinks [1]
08:32:21:master:INFO: Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:32:26:setup_element:INFO: Data phase scan results for group 0, downlink 1
08:32:26:setup_element:INFO: Eye window for uplink 8 : XXX__________________________________XXX
Data delay found: 19
08:32:26:setup_element:INFO: Eye window for uplink 9 : _XXXXX__________________________________
Data delay found: 23
08:32:26:setup_element:INFO: Eye window for uplink 10: XX_____________________XXXXXXXXXXXXXXXXX
Data delay found: 12
08:32:26:setup_element:INFO: Eye window for uplink 11: XX_____________________XXXXXXXXXXXXXXXXX
Data delay found: 12
08:32:26:setup_element:INFO: Eye window for uplink 12: XXXXX__________________________________X
Data delay found: 21
08:32:26:setup_element:INFO: Eye window for uplink 13: _XXXXX__________________________________
Data delay found: 23
08:32:26:setup_element:INFO: Eye window for uplink 14: X__________________________________XXXXX
Data delay found: 17
08:32:27:setup_element:INFO: Eye window for uplink 15: XX__________________________________XXXX
Data delay found: 18
08:32:27:setup_element:INFO: Setting the data phase to 19 for uplink 8
08:32:27:setup_element:INFO: Setting the data phase to 23 for uplink 9
08:32:27:setup_element:INFO: Setting the data phase to 12 for uplink 10
08:32:27:setup_element:INFO: Setting the data phase to 12 for uplink 11
08:32:27:setup_element:INFO: Setting the data phase to 21 for uplink 12
08:32:27:setup_element:INFO: Setting the data phase to 23 for uplink 13
08:32:27:setup_element:INFO: Setting the data phase to 17 for uplink 14
08:32:27:setup_element:INFO: Setting the data phase to 18 for uplink 15
==============================================OOO==============================================
08:32:27:setup_element:INFO: Beginning SMX ASICs map scan
08:32:27:master:INFO: Setting encoding mode SOS for groups [0], downlinks [1]
08:32:27:master:INFO: Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:32:27:master:INFO: Setting encoding mode EOS for groups [0], downlinks [1]
08:32:27:master:INFO: Setting encoding mode FRAME for groups [0], downlinks [1]
08:32:27:uplink:INFO: Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
08:32:27:setup_element:INFO: Adding ASIC 0x1, ASIC uplink 0, uplink 8
08:32:27:setup_element:INFO: Adding ASIC 0x1, ASIC uplink 1, uplink 9
08:32:27:setup_element:INFO: Adding ASIC 0x3, ASIC uplink 0, uplink 10
08:32:27:setup_element:INFO: Adding ASIC 0x3, ASIC uplink 1, uplink 11
08:32:27:setup_element:INFO: Adding ASIC 0x5, ASIC uplink 0, uplink 12
08:32:28:setup_element:INFO: Adding ASIC 0x5, ASIC uplink 1, uplink 13
08:32:28:setup_element:INFO: Adding ASIC 0x7, ASIC uplink 0, uplink 14
08:32:28:setup_element:INFO: Adding ASIC 0x7, ASIC uplink 1, uplink 15
08:32:29:ST3_emu:INFO:
Setup Element:
Group: 0
Downlink: 1
Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
ASICs Map:
ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
Clock Phase Characteristic:
Optimal Phase: 32
Window Length: 71
Eye Windows:
Uplink 8: _____________________________________________________________________XXXXXXXX___
Uplink 9: _____________________________________________________________________XXXXXXXX___
Uplink 10: ____________________________________________________________________XXXXXXX_____
Uplink 11: ____________________________________________________________________XXXXXXX_____
Uplink 12: _____________________________________________________________________XXXXXXXX___
Uplink 13: _____________________________________________________________________XXXXXXXX___
Uplink 14: ____________________________________________________________________XXXXXXXX____
Uplink 15: ____________________________________________________________________XXXXXXXX____
Data phase characteristics:
Uplink 8:
Optimal Phase: 19
Window Length: 34
Eye Window: XXX__________________________________XXX
Uplink 9:
Optimal Phase: 23
Window Length: 35
Eye Window: _XXXXX__________________________________
Uplink 10:
Optimal Phase: 12
Window Length: 21
Eye Window: XX_____________________XXXXXXXXXXXXXXXXX
Uplink 11:
Optimal Phase: 12
Window Length: 21
Eye Window: XX_____________________XXXXXXXXXXXXXXXXX
Uplink 12:
Optimal Phase: 21
Window Length: 34
Eye Window: XXXXX__________________________________X
Uplink 13:
Optimal Phase: 23
Window Length: 35
Eye Window: _XXXXX__________________________________
Uplink 14:
Optimal Phase: 17
Window Length: 34
Eye Window: X__________________________________XXXXX
Uplink 15:
Optimal Phase: 18
Window Length: 34
Eye Window: XX__________________________________XXXX
==============================================OOO==============================================
08:32:29:setup_element:INFO: Performing Elink synchronization
08:32:29:master:INFO: Setting encoding mode SOS for groups [0], downlinks [1]
08:32:29:master:INFO: Setting encoding mode K.28.1 for groups [0], downlinks [1]
08:32:29:master:INFO: Setting encoding mode EOS for groups [0], downlinks [1]
08:32:29:master:INFO: Setting encoding mode FRAME for groups [0], downlinks [1]
==============================================OOO==============================================
08:32:29:setup_element:INFO: Writing SMX Elink masks for group 0, downlink 1
08:32:29:uplink:INFO: Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
==============================================OOO==============================================
|_________________________________________________________________________|
_addr_|_upli_|_dwnli_|_grp_|_uplinks_|_#uplinks_|_uplinks_map_
1 | [0] | 1 | 0 | [8] | 2 | [(0, 8), (1, 9)]
3 | [0] | 1 | 0 | [10] | 2 | [(0, 10), (1, 11)]
5 | [0] | 1 | 0 | [12] | 2 | [(0, 12), (1, 13)]
7 | [0] | 1 | 0 | [14] | 2 | [(0, 14), (1, 15)]
|_________________________________________________________________________|
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
08:32:30:febtest:INFO: Init all SMX (CSA): 30
08:32:37:febtest:INFO: _Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
08:32:37:febtest:INFO: 08-01 | XA-000-09-004-021-016-010-04 | 34.6 | 1141.9
08:32:38:febtest:INFO: 10-03 | XA-000-09-004-021-010-012-07 | 31.4 | 1165.6
08:32:38:febtest:INFO: 12-05 | XA-000-09-004-021-016-011-04 | 21.9 | 1195.1
08:32:38:febtest:INFO: 14-07 | XA-000-09-004-021-013-012-15 | 31.4 | 1171.5
08:32:39:febtest:INFO: Set all CSA to ZERO
FEB type: A FEB_A: 1 FEB_B: 0
08:32:41:ST3_smx:INFO: chip: 8-1 37.726682 C 1147.806000 mV
08:32:41:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:41:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:41:ST3_smx:INFO: Electrons
08:32:46:ST3_smx:INFO: Total # of broken channels: 8
08:32:46:ST3_smx:INFO: List of broken channels: [35, 40, 41, 47, 50, 51, 68, 116]
08:32:46:ST3_smx:INFO: Total # of broken channels: 0
08:32:46:ST3_smx:INFO: List of broken channels: []
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
08:32:48:ST3_smx:INFO: chip: 10-3 31.389742 C 1171.483840 mV
08:32:48:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:48:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:48:ST3_smx:INFO: Electrons
08:32:52:ST3_smx:INFO: Total # of broken channels: 4
08:32:52:ST3_smx:INFO: List of broken channels: [15, 75, 80, 104]
08:32:52:ST3_smx:INFO: Total # of broken channels: 0
08:32:52:ST3_smx:INFO: List of broken channels: []
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
08:32:54:ST3_smx:INFO: chip: 12-5 25.062742 C 1200.969315 mV
08:32:54:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:54:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:32:54:ST3_smx:INFO: Electrons
08:32:59:ST3_smx:INFO: Total # of broken channels: 4
08:32:59:ST3_smx:INFO: List of broken channels: [42, 78, 87, 120]
08:32:59:ST3_smx:INFO: Total # of broken channels: 0
08:32:59:ST3_smx:INFO: List of broken channels: []
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
08:33:00:ST3_smx:INFO: chip: 14-7 34.556970 C 1183.292940 mV
08:33:00:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:33:00:ST3_discr_histo:WARNING: Not enough entries for fit!!!
08:33:00:ST3_smx:INFO: Electrons
08:33:05:ST3_smx:INFO: Total # of broken channels: 6
08:33:05:ST3_smx:INFO: List of broken channels: [68, 70, 87, 88, 98, 105]
08:33:05:ST3_smx:INFO: Total # of broken channels: 0
08:33:05:ST3_smx:INFO: List of broken channels: []
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
THistPainter::MakeChopt:0: RuntimeWarning: option SCAT is deprecated.
08:33:05:febtest:INFO: _Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
08:33:06:febtest:INFO: 08-01 | XA-000-09-004-021-016-010-04 | 34.6 | 1171.5
08:33:06:febtest:INFO: 10-03 | XA-000-09-004-021-010-012-07 | 31.4 | 1195.1
08:33:06:febtest:INFO: 12-05 | XA-000-09-004-021-016-011-04 | 25.1 | 1224.5
08:33:06:febtest:INFO: 14-07 | XA-000-09-004-021-013-012-15 | 34.6 | 1201.0
{'CSA_FRONT': 55, 'IFED': 31, 'PSC_BIAS': 131, 'SH_BIAS': 55, 'AMP_CAL': 0, 'SH_SLOW': 0, 'IREF_FAST': 32, 'THR2_GLB': 30, 'ADC_VREF_N': 30, 'ADC_VREF_P': 58, 'ADC_VREF_T': 128, 'CAL_STROBE': 64, 'IN_CSAP': 30, 'CSA_BACK': 55, 'CSA_CAS_BUF': 27, 'SH_CAS_BUF': 27, 'CSA_BIAS': 91, 'DAC_THR1': 0, 'ADC_VREF_TR': 122, 'DIAG_IBIAS': 31}
===============================
{'CSA_FRONT': 55, 'IFED': 31, 'PSC_BIAS': 131, 'SH_BIAS': 55, 'AMP_CAL': 0, 'SH_SLOW': 0, 'IREF_FAST': 32, 'THR2_GLB': 30, 'ADC_VREF_N': 30, 'ADC_VREF_P': 58, 'ADC_VREF_T': 128, 'CAL_STROBE': 64, 'IN_CSAP': 30, 'CSA_BACK': 55, 'CSA_CAS_BUF': 27, 'SH_CAS_BUF': 27, 'CSA_BIAS': 91, 'DAC_THR1': 0, 'ADC_VREF_TR': 122, 'DIAG_IBIAS': 31}
===============================
{'CSA_FRONT': 55, 'IFED': 31, 'PSC_BIAS': 131, 'SH_BIAS': 55, 'AMP_CAL': 0, 'SH_SLOW': 0, 'IREF_FAST': 32, 'THR2_GLB': 30, 'ADC_VREF_N': 30, 'ADC_VREF_P': 58, 'ADC_VREF_T': 128, 'CAL_STROBE': 64, 'IN_CSAP': 30, 'CSA_BACK': 55, 'CSA_CAS_BUF': 27, 'SH_CAS_BUF': 27, 'CSA_BIAS': 91, 'DAC_THR1': 0, 'ADC_VREF_TR': 122, 'DIAG_IBIAS': 31}
===============================
{'CSA_FRONT': 55, 'IFED': 31, 'PSC_BIAS': 131, 'SH_BIAS': 55, 'AMP_CAL': 0, 'SH_SLOW': 0, 'IREF_FAST': 32, 'THR2_GLB': 30, 'ADC_VREF_N': 30, 'ADC_VREF_P': 58, 'ADC_VREF_T': 128, 'CAL_STROBE': 64, 'IN_CSAP': 30, 'CSA_BACK': 55, 'CSA_CAS_BUF': 27, 'SH_CAS_BUF': 27, 'CSA_BIAS': 91, 'DAC_THR1': 0, 'ADC_VREF_TR': 122, 'DIAG_IBIAS': 31}
===============================
############################################################
# S U M M A R Y #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 25_11_25-08_32_18
OPERATOR : Oleksandr S.;
SITE : GSI | SETUP : GSI_TEST_SETUP_1
------------------------------------------------------------
| FEB_SN : 1515| FEB_TYPE : 8.2| FEB_UPLINKS : 2| FEB_A
AMP_MODE : STS
------------------------------------------------------------
------------------------------------------------------------
VI_before_Init : ['2.449', '0.7745', '1.850', '0.9465', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '1.0290', '1.850', '1.1890', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '0.9962', '1.850', '0.2671', '0.000', '0.0000', '0.000', '0.0000']