XA-000-08-002-000-004-191-11 05.06.23 08:52:18
ADC4
SMX_7
CSA
Calibration
ADC
CSA
Info
TEST_NAME : Microcable
TEST_DATE : 2023_06_05-08_52_18
OPERATOR : Kerstin
Set-ID : 0225L016-M000 | side-P | index: (1/8) | Spare
---------------------------------------
---------------------------------------
ASIC_CONFIG_PARAMETERS
HW_ADDR : 0x7 | VERS_NO : 2.2
ASIC_ID : XA-000-08-002-000-004-191-11 | FUSED_ID : 6359364699116555259
IC_TEMP : 16.24 | VDDM : 1114.63 | AUX_INT : 0.00 | CsaBias : 138.98
CONF_FAIL_REG : 0
CSA_BIAS : 15
THR2_GLB : 30
ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122
ADC_Chi2/NDF : 3.60149e-05 / 1
ADC_P0 : 0.00000e+00 ± 6.00124e-03
ADC_P1 : 7.40150e-03 ± 9.83841e-05
ADC_P2 : -4.56439e-06 ± 5.55505e-07
CSA_Chi2/NDF : 4.79352e-04 / 1
CSA_P0 : 6.82875e-02 ± 8.24064e-03
CSA_P1 : 8.62917e-03 ± 6.11059e-04
CSA_P2 : -1.41755e-05 ± 9.32615e-06
---------------------------------------
N_BROKEN_DISC : 0 | N_BROKEN_FAST : []
N_BROKEN_CABLE : 0
LIST_OF_BROKEN_CABLES : []
---------------------------------------
VI_before_Init : ['1.196', '0.1838', '1.801', '0.0857', '1.800', '0.0990', '7.000', '0.6769']
VI_after__Init : ['1.200', '0.1849', '1.800', '0.0853', '1.800', '0.1496', '7.000', '0.6811']
VI_at__the_End : ['1.200', '0.5477', '1.800', '0.0755', '1.800', '0.1715', '7.000', '0.6821']