XA-000-08-002-003-006-033-04 01.07.24 12:58:11
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 24_07_01-12_58_11 OPERATOR : Alois Alzheimer SITE : GSI | SETUP : GSI_TEST_SETUP_2 ------------------------------------------------------------ ------------------------------------------------------------ ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-002-003-006-033-04 | FUSED_ID : 6359364699119706644 IC_TEMP : -2.84 | VDDM : 1040.97 | AUX_INT : 0.00 | CsaBias : 83.55 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 3.04054e-05 / 3 ADC_P0 : 0.00000e+00 ± 3.18357e-03 ADC_P1 : 7.66796e-03 ± 4.87805e-05 ADC_P2 : -6.60864e-06 ± 2.72334e-07 CSA_Chi2/NDF : 1.69759e-04 / 3 CSA_P0 : 4.25458e-02 ± 4.90399e-03 CSA_P1 : 1.07232e-02 ± 3.63640e-04 CSA_P2 : -6.01337e-05 ± 5.54998e-06 ------------------------------------------------------------ Set-ID : 0592L023-M004 | side-P | index: (5/8) N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] ------------------------------------------------------------ VI_before_Init : ['1.201', '0.3329', '1.800', '0.1740', '1.800', '0.0428', '7.000', '1.4240'] VI_after__Init : ['1.200', '0.3338', '1.800', '0.1729', '1.800', '0.0732', '7.000', '1.4270'] VI_at__the_End : ['1.200', '0.4694', '1.800', '0.1519', '1.800', '0.0957', '7.000', '1.4280']