FEB_3005    11.03.24 11:58:10

TextEdit.txt
            11:58:10:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
11:58:10:ST3_Shared:INFO:	                       FEB-Microcable                       
11:58:10:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
11:58:11:febtest:INFO:	Testing FEB with SN 3005
11:58:13:smx_tester:INFO:	Scanning setup
11:58:13:elinks:INFO:	Disabling clock on downlink 0
11:58:13:elinks:INFO:	Disabling clock on downlink 1
11:58:13:elinks:INFO:	Disabling clock on downlink 2
11:58:13:elinks:INFO:	Disabling clock on downlink 3
11:58:13:elinks:INFO:	Disabling clock on downlink 4
11:58:13:setup_element:INFO:	Checking SOS, encoding_mode: SOS
11:58:13:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
11:58:13:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
11:58:13:elinks:INFO:	Disabling clock on downlink 0
11:58:13:elinks:INFO:	Disabling clock on downlink 1
11:58:13:elinks:INFO:	Disabling clock on downlink 2
11:58:13:elinks:INFO:	Disabling clock on downlink 3
11:58:13:elinks:INFO:	Disabling clock on downlink 4
11:58:13:setup_element:INFO:	Checking SOS, encoding_mode: SOS
11:58:13:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
11:58:14:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
11:58:14:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
11:58:14:elinks:INFO:	Disabling clock on downlink 0
11:58:14:elinks:INFO:	Disabling clock on downlink 1
11:58:14:elinks:INFO:	Disabling clock on downlink 2
11:58:14:elinks:INFO:	Disabling clock on downlink 3
11:58:14:elinks:INFO:	Disabling clock on downlink 4
11:58:14:setup_element:INFO:	Checking SOS, encoding_mode: SOS
11:58:14:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
11:58:14:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
11:58:14:elinks:INFO:	Disabling clock on downlink 0
11:58:14:elinks:INFO:	Disabling clock on downlink 1
11:58:14:elinks:INFO:	Disabling clock on downlink 2
11:58:14:elinks:INFO:	Disabling clock on downlink 3
11:58:14:elinks:INFO:	Disabling clock on downlink 4
11:58:14:setup_element:INFO:	Checking SOS, encoding_mode: SOS
11:58:14:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
11:58:14:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
11:58:14:elinks:INFO:	Disabling clock on downlink 0
11:58:14:elinks:INFO:	Disabling clock on downlink 1
11:58:14:elinks:INFO:	Disabling clock on downlink 2
11:58:14:elinks:INFO:	Disabling clock on downlink 3
11:58:14:elinks:INFO:	Disabling clock on downlink 4
11:58:14:setup_element:INFO:	Checking SOS, encoding_mode: SOS
11:58:14:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
11:58:14:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
11:58:14:setup_element:INFO:	Scanning clock phase
11:58:14:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
11:58:14:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
11:58:14:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
11:58:14:setup_element:INFO:	Eye window for uplink 8 : ________________________________________________________________________XXXXX___
Clock Delay: 34
11:58:14:setup_element:INFO:	Eye window for uplink 9 : ________________________________________________________________________XXXXX___
Clock Delay: 34
11:58:14:setup_element:INFO:	Eye window for uplink 10: _______________________________________________________________________XXXXX____
Clock Delay: 33
11:58:14:setup_element:INFO:	Eye window for uplink 11: _______________________________________________________________________XXXXX____
Clock Delay: 33
11:58:14:setup_element:INFO:	Eye window for uplink 12: _________________________________________________________________________XXXXXX_
Clock Delay: 35
11:58:14:setup_element:INFO:	Eye window for uplink 13: _________________________________________________________________________XXXXXX_
Clock Delay: 35
11:58:14:setup_element:INFO:	Eye window for uplink 14: _________________________________________________________________________XXXXXX_
Clock Delay: 35
11:58:14:setup_element:INFO:	Eye window for uplink 15: _________________________________________________________________________XXXXXX_
Clock Delay: 35
11:58:14:setup_element:INFO:	Setting the clock phase to 34 for group 0, downlink 1
11:58:14:setup_element:INFO:	Scanning data phases
11:58:14:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
11:58:14:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
11:58:19:setup_element:INFO:	Data phase scan results for group 0, downlink 1
11:58:19:setup_element:INFO:	Eye window for uplink 8 : ________________________XXXXX___________
Data delay found: 6
11:58:19:setup_element:INFO:	Eye window for uplink 9 : ____________________________XXXXX_______
Data delay found: 10
11:58:19:setup_element:INFO:	Eye window for uplink 10: ________________________XXXXX___________
Data delay found: 6
11:58:19:setup_element:INFO:	Eye window for uplink 11: ___________________________XXXXX________
Data delay found: 9
11:58:19:setup_element:INFO:	Eye window for uplink 12: __________________________XXXXX_________
Data delay found: 8
11:58:19:setup_element:INFO:	Eye window for uplink 13: ______________________________XXXXX_____
Data delay found: 12
11:58:19:setup_element:INFO:	Eye window for uplink 14: _____________________________XXXX_______
Data delay found: 10
11:58:19:setup_element:INFO:	Eye window for uplink 15: _______________________________XXXXX____
Data delay found: 13
11:58:19:setup_element:INFO:	Setting the data phase to 6 for uplink 8
11:58:19:setup_element:INFO:	Setting the data phase to 10 for uplink 9
11:58:19:setup_element:INFO:	Setting the data phase to 6 for uplink 10
11:58:19:setup_element:INFO:	Setting the data phase to 9 for uplink 11
11:58:19:setup_element:INFO:	Setting the data phase to 8 for uplink 12
11:58:19:setup_element:INFO:	Setting the data phase to 12 for uplink 13
11:58:19:setup_element:INFO:	Setting the data phase to 10 for uplink 14
11:58:19:setup_element:INFO:	Setting the data phase to 13 for uplink 15
11:58:19:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 34
    Window Length: 72
    Eye Windows:
      Uplink  8: ________________________________________________________________________XXXXX___
      Uplink  9: ________________________________________________________________________XXXXX___
      Uplink 10: _______________________________________________________________________XXXXX____
      Uplink 11: _______________________________________________________________________XXXXX____
      Uplink 12: _________________________________________________________________________XXXXXX_
      Uplink 13: _________________________________________________________________________XXXXXX_
      Uplink 14: _________________________________________________________________________XXXXXX_
      Uplink 15: _________________________________________________________________________XXXXXX_
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 9:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 10:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 11:
      Optimal Phase: 9
      Window Length: 35
      Eye Window: ___________________________XXXXX________
    Uplink 12:
      Optimal Phase: 8
      Window Length: 35
      Eye Window: __________________________XXXXX_________
    Uplink 13:
      Optimal Phase: 12
      Window Length: 35
      Eye Window: ______________________________XXXXX_____
    Uplink 14:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 15:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____
]
11:58:19:setup_element:INFO:	Beginning SMX ASICs map scan
11:58:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
11:58:19:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
11:58:19:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
11:58:19:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
11:58:19:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
11:58:20:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
11:58:20:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
11:58:20:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
11:58:20:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
11:58:20:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
11:58:20:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
11:58:21:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
11:58:21:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
11:58:22:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 34
    Window Length: 72
    Eye Windows:
      Uplink  8: ________________________________________________________________________XXXXX___
      Uplink  9: ________________________________________________________________________XXXXX___
      Uplink 10: _______________________________________________________________________XXXXX____
      Uplink 11: _______________________________________________________________________XXXXX____
      Uplink 12: _________________________________________________________________________XXXXXX_
      Uplink 13: _________________________________________________________________________XXXXXX_
      Uplink 14: _________________________________________________________________________XXXXXX_
      Uplink 15: _________________________________________________________________________XXXXXX_
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 9:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 10:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 11:
      Optimal Phase: 9
      Window Length: 35
      Eye Window: ___________________________XXXXX________
    Uplink 12:
      Optimal Phase: 8
      Window Length: 35
      Eye Window: __________________________XXXXX_________
    Uplink 13:
      Optimal Phase: 12
      Window Length: 35
      Eye Window: ______________________________XXXXX_____
    Uplink 14:
      Optimal Phase: 10
      Window Length: 36
      Eye Window: _____________________________XXXX_______
    Uplink 15:
      Optimal Phase: 13
      Window Length: 35
      Eye Window: _______________________________XXXXX____

11:58:22:setup_element:INFO:	Performing Elink synchronization
11:58:22:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
11:58:22:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
11:58:22:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
11:58:22:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
11:58:22:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
11:58:22:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
11:58:22:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_1_8 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_1_8 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_1__upli_8
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_3_10 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_3_10 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_3__upli_10
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
11:58:23:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
11:58:23:febtest:INFO:	08-01 | XA-000-08-003-000-001-121-05 |  31.4 | 1230.3
11:58:24:febtest:INFO:	10-03 | XA-000-08-003-000-001-118-05 |  47.3 | 1183.3
11:58:24:febtest:INFO:	12-05 | XA-000-08-003-000-001-114-05 |  47.3 | 1177.4
11:58:24:febtest:INFO:	14-07 | XA-000-08-003-000-001-122-05 |  21.9 | 1271.2
11:58:24:ST3_smx:INFO:	Configuring SMX FAST
11:58:26:ST3_smx:INFO:	chip: 8-1 	 44.073563 C 	 1183.292940 mV
11:58:26:ST3_smx:INFO:		Electrons
11:58:26:ST3_smx:INFO:	# loops 0
11:58:27:ST3_smx:INFO:	# loops 1
11:58:29:ST3_smx:INFO:	# loops 2
11:58:30:ST3_smx:INFO:	Total # of broken channels: 0
11:58:30:ST3_smx:INFO:	List of broken channels: []
11:58:30:ST3_smx:INFO:	Total # of broken channels: 0
11:58:30:ST3_smx:INFO:	List of broken channels: []
11:58:31:ST3_smx:INFO:	Configuring SMX FAST
11:58:33:ST3_smx:INFO:	chip: 10-3 	 47.250730 C 	 1177.390875 mV
11:58:33:ST3_smx:INFO:		Electrons
11:58:33:ST3_smx:INFO:	# loops 0
11:58:35:ST3_smx:INFO:	# loops 1
11:58:36:ST3_smx:INFO:	# loops 2
11:58:38:ST3_smx:INFO:	Total # of broken channels: 0
11:58:38:ST3_smx:INFO:	List of broken channels: []
11:58:38:ST3_smx:INFO:	Total # of broken channels: 0
11:58:38:ST3_smx:INFO:	List of broken channels: []
11:58:39:ST3_smx:INFO:	Configuring SMX FAST
11:58:41:ST3_smx:INFO:	chip: 12-5 	 40.898880 C 	 1206.851500 mV
11:58:41:ST3_smx:INFO:		Electrons
11:58:41:ST3_smx:INFO:	# loops 0
11:58:42:ST3_smx:INFO:	# loops 1
11:58:44:ST3_smx:INFO:	# loops 2
11:58:45:ST3_smx:INFO:	Total # of broken channels: 0
11:58:45:ST3_smx:INFO:	List of broken channels: []
11:58:45:ST3_smx:INFO:	Total # of broken channels: 0
11:58:45:ST3_smx:INFO:	List of broken channels: []
11:58:46:ST3_smx:INFO:	Configuring SMX FAST
11:58:48:ST3_smx:INFO:	chip: 14-7 	 28.225000 C 	 1253.730060 mV
11:58:48:ST3_smx:INFO:		Electrons
11:58:48:ST3_smx:INFO:	# loops 0
11:58:49:ST3_smx:INFO:	# loops 1
11:58:51:ST3_smx:INFO:	# loops 2
11:58:52:ST3_smx:INFO:	Total # of broken channels: 0
11:58:52:ST3_smx:INFO:	List of broken channels: []
11:58:52:ST3_smx:INFO:	Total # of broken channels: 0
11:58:52:ST3_smx:INFO:	List of broken channels: []
11:58:53:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
11:58:54:febtest:INFO:	08-01 | XA-000-08-003-000-001-121-05 |  44.1 | 1189.2
11:58:54:febtest:INFO:	10-03 | XA-000-08-003-000-001-118-05 |  47.3 | 1183.3
11:58:54:febtest:INFO:	12-05 | XA-000-08-003-000-001-114-05 |  40.9 | 1206.9
11:58:54:febtest:INFO:	14-07 | XA-000-08-003-000-001-122-05 |  28.2 | 1253.7
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_03_11-11_58_10
OPERATOR  : Henrik; Irakli; 
SITE      : KIT
SETUP     : KIT_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : 
FEB_SN : 3005
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.200', '0.9293', '2.801', '1.4070', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.200', '0.9826', '2.800', '0.2938', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.200', '0.9792', '2.800', '0.1679', '0.000', '0.0000', '0.000', '0.0000']