FEB_3008    20.03.24 10:50:16

TextEdit.txt
            10:50:16:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
10:50:16:ST3_Shared:INFO:	                       FEB-Microcable                       
10:50:16:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
10:50:16:febtest:INFO:	Testing FEB with SN 3008
10:50:19:smx_tester:INFO:	Scanning setup
10:50:19:elinks:INFO:	Disabling clock on downlink 0
10:50:19:elinks:INFO:	Disabling clock on downlink 1
10:50:19:elinks:INFO:	Disabling clock on downlink 2
10:50:19:elinks:INFO:	Disabling clock on downlink 3
10:50:19:elinks:INFO:	Disabling clock on downlink 4
10:50:19:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:50:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
10:50:19:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:50:19:elinks:INFO:	Disabling clock on downlink 0
10:50:19:elinks:INFO:	Disabling clock on downlink 1
10:50:19:elinks:INFO:	Disabling clock on downlink 2
10:50:19:elinks:INFO:	Disabling clock on downlink 3
10:50:19:elinks:INFO:	Disabling clock on downlink 4
10:50:19:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:50:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
10:50:19:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
10:50:19:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:50:19:elinks:INFO:	Disabling clock on downlink 0
10:50:19:elinks:INFO:	Disabling clock on downlink 1
10:50:19:elinks:INFO:	Disabling clock on downlink 2
10:50:19:elinks:INFO:	Disabling clock on downlink 3
10:50:19:elinks:INFO:	Disabling clock on downlink 4
10:50:19:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:50:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
10:50:19:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:50:19:elinks:INFO:	Disabling clock on downlink 0
10:50:19:elinks:INFO:	Disabling clock on downlink 1
10:50:19:elinks:INFO:	Disabling clock on downlink 2
10:50:19:elinks:INFO:	Disabling clock on downlink 3
10:50:19:elinks:INFO:	Disabling clock on downlink 4
10:50:19:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:50:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
10:50:19:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:50:19:elinks:INFO:	Disabling clock on downlink 0
10:50:19:elinks:INFO:	Disabling clock on downlink 1
10:50:19:elinks:INFO:	Disabling clock on downlink 2
10:50:19:elinks:INFO:	Disabling clock on downlink 3
10:50:19:elinks:INFO:	Disabling clock on downlink 4
10:50:19:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:50:19:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
10:50:20:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:50:20:setup_element:INFO:	Scanning clock phase
10:50:20:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:50:20:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:50:20:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
10:50:20:setup_element:INFO:	Eye window for uplink 8 : ________________________________________________________________________XXXXX___
Clock Delay: 34
10:50:20:setup_element:INFO:	Eye window for uplink 9 : ________________________________________________________________________XXXXX___
Clock Delay: 34
10:50:20:setup_element:INFO:	Eye window for uplink 10: ___________________________________________________________________________XXXXX
Clock Delay: 37
10:50:20:setup_element:INFO:	Eye window for uplink 11: ___________________________________________________________________________XXXXX
Clock Delay: 37
10:50:20:setup_element:INFO:	Eye window for uplink 12: _____________________________________________________________________XXXXXX_____
Clock Delay: 31
10:50:20:setup_element:INFO:	Eye window for uplink 13: _____________________________________________________________________XXXXXX_____
Clock Delay: 31
10:50:20:setup_element:INFO:	Eye window for uplink 14: __________________________________________________________________________XXXXX_
Clock Delay: 36
10:50:20:setup_element:INFO:	Eye window for uplink 15: __________________________________________________________________________XXXXX_
Clock Delay: 36
10:50:20:setup_element:INFO:	Setting the clock phase to 34 for group 0, downlink 1
10:50:20:setup_element:INFO:	Scanning data phases
10:50:20:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:50:20:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:50:25:setup_element:INFO:	Data phase scan results for group 0, downlink 1
10:50:25:setup_element:INFO:	Eye window for uplink 8 : ______________________XXXXXX____________
Data delay found: 4
10:50:25:setup_element:INFO:	Eye window for uplink 9 : ___________________________XXXXX________
Data delay found: 9
10:50:25:setup_element:INFO:	Eye window for uplink 10: ____________________________XXXXXX______
Data delay found: 10
10:50:25:setup_element:INFO:	Eye window for uplink 11: ________________________________XXXXXX__
Data delay found: 14
10:50:25:setup_element:INFO:	Eye window for uplink 12: _______________________XXXX_____________
Data delay found: 4
10:50:25:setup_element:INFO:	Eye window for uplink 13: __________________________XXXXX_________
Data delay found: 8
10:50:25:setup_element:INFO:	Eye window for uplink 14: ____________________________XXXXX_______
Data delay found: 10
10:50:25:setup_element:INFO:	Eye window for uplink 15: _______________________________XXXX_____
Data delay found: 12
10:50:25:setup_element:INFO:	Setting the data phase to 4 for uplink 8
10:50:25:setup_element:INFO:	Setting the data phase to 9 for uplink 9
10:50:25:setup_element:INFO:	Setting the data phase to 10 for uplink 10
10:50:25:setup_element:INFO:	Setting the data phase to 14 for uplink 11
10:50:25:setup_element:INFO:	Setting the data phase to 4 for uplink 12
10:50:25:setup_element:INFO:	Setting the data phase to 8 for uplink 13
10:50:25:setup_element:INFO:	Setting the data phase to 10 for uplink 14
10:50:25:setup_element:INFO:	Setting the data phase to 12 for uplink 15
10:50:25:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 34
    Window Length: 69
    Eye Windows:
      Uplink  8: ________________________________________________________________________XXXXX___
      Uplink  9: ________________________________________________________________________XXXXX___
      Uplink 10: ___________________________________________________________________________XXXXX
      Uplink 11: ___________________________________________________________________________XXXXX
      Uplink 12: _____________________________________________________________________XXXXXX_____
      Uplink 13: _____________________________________________________________________XXXXXX_____
      Uplink 14: __________________________________________________________________________XXXXX_
      Uplink 15: __________________________________________________________________________XXXXX_
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 4
      Window Length: 34
      Eye Window: ______________________XXXXXX____________
    Uplink 9:
      Optimal Phase: 9
      Window Length: 35
      Eye Window: ___________________________XXXXX________
    Uplink 10:
      Optimal Phase: 10
      Window Length: 34
      Eye Window: ____________________________XXXXXX______
    Uplink 11:
      Optimal Phase: 14
      Window Length: 34
      Eye Window: ________________________________XXXXXX__
    Uplink 12:
      Optimal Phase: 4
      Window Length: 36
      Eye Window: _______________________XXXX_____________
    Uplink 13:
      Optimal Phase: 8
      Window Length: 35
      Eye Window: __________________________XXXXX_________
    Uplink 14:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 15:
      Optimal Phase: 12
      Window Length: 36
      Eye Window: _______________________________XXXX_____
]
10:50:25:setup_element:INFO:	Beginning SMX ASICs map scan
10:50:25:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:50:25:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:50:25:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
10:50:25:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
10:50:25:uplink:INFO:	Setting uplinks mask [8, 9, 10, 11, 12, 13, 14, 15]
10:50:25:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
10:50:25:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
10:50:26:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
10:50:26:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
10:50:26:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
10:50:26:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
10:50:26:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
10:50:26:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
10:50:28:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 34
    Window Length: 69
    Eye Windows:
      Uplink  8: ________________________________________________________________________XXXXX___
      Uplink  9: ________________________________________________________________________XXXXX___
      Uplink 10: ___________________________________________________________________________XXXXX
      Uplink 11: ___________________________________________________________________________XXXXX
      Uplink 12: _____________________________________________________________________XXXXXX_____
      Uplink 13: _____________________________________________________________________XXXXXX_____
      Uplink 14: __________________________________________________________________________XXXXX_
      Uplink 15: __________________________________________________________________________XXXXX_
  Data phase characteristics:
    Uplink 8:
      Optimal Phase: 4
      Window Length: 34
      Eye Window: ______________________XXXXXX____________
    Uplink 9:
      Optimal Phase: 9
      Window Length: 35
      Eye Window: ___________________________XXXXX________
    Uplink 10:
      Optimal Phase: 10
      Window Length: 34
      Eye Window: ____________________________XXXXXX______
    Uplink 11:
      Optimal Phase: 14
      Window Length: 34
      Eye Window: ________________________________XXXXXX__
    Uplink 12:
      Optimal Phase: 4
      Window Length: 36
      Eye Window: _______________________XXXX_____________
    Uplink 13:
      Optimal Phase: 8
      Window Length: 35
      Eye Window: __________________________XXXXX_________
    Uplink 14:
      Optimal Phase: 10
      Window Length: 35
      Eye Window: ____________________________XXXXX_______
    Uplink 15:
      Optimal Phase: 12
      Window Length: 36
      Eye Window: _______________________________XXXX_____

10:50:28:setup_element:INFO:	Performing Elink synchronization
10:50:28:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:50:28:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:50:28:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
10:50:28:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
10:50:28:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
10:50:28:uplink:INFO:	Enabling uplinks [8, 9, 10, 11, 12, 13, 14, 15]
10:50:28:ST3_emu:INFO:	Number of chips: 4
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_5_12 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_5_12 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_5__upli_12
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_h_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: h2D_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_fastD_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_front_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hDist_back_e_7_14 (Potential memory leak).
TROOT::Append:0: RuntimeWarning: Replacing existing TH1: hBroken_e_7_14 (Potential memory leak).
TCanvas::Constructor:0: RuntimeWarning: Deleting canvas with same name: cDist_FEB_A__addr_7__upli_14
FEB type: A FEB_A: 1 FEB_B: 0
10:50:29:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
10:50:29:febtest:INFO:	08-01 | XA-000-08-003-000-001-039-07 |  44.1 | 1177.4
10:50:29:febtest:INFO:	10-03 | XA-000-08-003-000-001-043-07 |  25.1 | 1242.0
10:50:29:febtest:INFO:	12-05 | XA-000-08-003-000-001-045-07 |  37.7 | 1206.9
10:50:30:febtest:INFO:	14-07 | XA-000-08-003-000-001-040-07 |  37.7 | 1212.7
10:50:30:ST3_smx:INFO:	Configuring SMX FAST
10:50:31:ST3_smx:INFO:	chip: 8-1 	 47.250730 C 	 1165.571835 mV
10:50:31:ST3_smx:INFO:		Electrons
10:50:31:ST3_smx:INFO:	# loops 0
10:50:33:ST3_smx:INFO:	# loops 1
10:50:35:ST3_smx:INFO:	# loops 2
10:50:36:ST3_smx:INFO:	Total # of broken channels: 0
10:50:36:ST3_smx:INFO:	List of broken channels: []
10:50:36:ST3_smx:INFO:	Total # of broken channels: 0
10:50:36:ST3_smx:INFO:	List of broken channels: []
10:50:37:ST3_smx:INFO:	Configuring SMX FAST
10:50:39:ST3_smx:INFO:	chip: 10-3 	 34.556970 C 	 1212.728715 mV
10:50:39:ST3_smx:INFO:		Electrons
10:50:39:ST3_smx:INFO:	# loops 0
10:50:41:ST3_smx:INFO:	# loops 1
10:50:43:ST3_smx:INFO:	# loops 2
10:50:45:ST3_smx:INFO:	Total # of broken channels: 0
10:50:45:ST3_smx:INFO:	List of broken channels: []
10:50:45:ST3_smx:INFO:	Total # of broken channels: 0
10:50:45:ST3_smx:INFO:	List of broken channels: []
10:50:46:ST3_smx:INFO:	Configuring SMX FAST
10:50:48:ST3_smx:INFO:	chip: 12-5 	 34.556970 C 	 1206.851500 mV
10:50:48:ST3_smx:INFO:		Electrons
10:50:48:ST3_smx:INFO:	# loops 0
10:50:50:ST3_smx:INFO:	# loops 1
10:50:52:ST3_smx:INFO:	# loops 2
10:50:54:ST3_smx:INFO:	Total # of broken channels: 0
10:50:54:ST3_smx:INFO:	List of broken channels: []
10:50:54:ST3_smx:INFO:	Total # of broken channels: 0
10:50:54:ST3_smx:INFO:	List of broken channels: []
10:50:55:ST3_smx:INFO:	Configuring SMX FAST
10:50:57:ST3_smx:INFO:	chip: 14-7 	 47.250730 C 	 1183.292940 mV
10:50:57:ST3_smx:INFO:		Electrons
10:50:57:ST3_smx:INFO:	# loops 0
10:50:59:ST3_smx:INFO:	# loops 1
10:51:00:ST3_smx:INFO:	# loops 2
10:51:02:ST3_smx:INFO:	Total # of broken channels: 0
10:51:02:ST3_smx:INFO:	List of broken channels: []
10:51:02:ST3_smx:INFO:	Total # of broken channels: 0
10:51:02:ST3_smx:INFO:	List of broken channels: []
10:51:03:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
10:51:03:febtest:INFO:	08-01 | XA-000-08-003-000-001-039-07 |  47.3 | 1177.4
10:51:03:febtest:INFO:	10-03 | XA-000-08-003-000-001-043-07 |  31.4 | 1218.6
10:51:03:febtest:INFO:	12-05 | XA-000-08-003-000-001-045-07 |  34.6 | 1218.6
10:51:04:febtest:INFO:	14-07 | XA-000-08-003-000-001-040-07 |  47.3 | 1183.3
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_03_20-10_50_16
OPERATOR  : Henrik; 
SITE      : KIT
SETUP     : KIT_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : L5UL301017 M5UL3T3010173B2 124 C

FEB_SN : 3008
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.200', '0.6933', '2.801', '1.1630', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.200', '0.9998', '2.800', '0.3912', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.200', '0.9958', '2.800', '0.1700', '0.000', '0.0000', '0.000', '0.0000']