FEB_3030    11.06.24 10:00:55

TextEdit.txt
            10:00:55:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
10:00:55:ST3_Shared:INFO:	                       FEB-Microcable                       
10:00:55:ST3_Shared:INFO:	oooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
10:00:55:febtest:INFO:	Testing FEB with SN 3030
10:00:58:smx_tester:INFO:	Scanning setup
10:00:58:elinks:INFO:	Disabling clock on downlink 0
10:00:58:elinks:INFO:	Disabling clock on downlink 1
10:00:58:elinks:INFO:	Disabling clock on downlink 2
10:00:58:elinks:INFO:	Disabling clock on downlink 3
10:00:58:elinks:INFO:	Disabling clock on downlink 4
10:00:58:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:00:58:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [0]
10:00:58:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:00:58:elinks:INFO:	Disabling clock on downlink 0
10:00:58:elinks:INFO:	Disabling clock on downlink 1
10:00:58:elinks:INFO:	Disabling clock on downlink 2
10:00:58:elinks:INFO:	Disabling clock on downlink 3
10:00:58:elinks:INFO:	Disabling clock on downlink 4
10:00:58:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:00:58:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 0
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 1
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 2
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 3
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 4
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 5
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 6
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 7
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 8
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 9
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 10
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 11
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 12
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 13
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 14
10:00:58:setup_element:INFO:	SOS detected for group 0, downlink 1, uplink 15
10:00:58:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:00:58:elinks:INFO:	Disabling clock on downlink 0
10:00:58:elinks:INFO:	Disabling clock on downlink 1
10:00:58:elinks:INFO:	Disabling clock on downlink 2
10:00:58:elinks:INFO:	Disabling clock on downlink 3
10:00:58:elinks:INFO:	Disabling clock on downlink 4
10:00:58:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:00:58:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [2]
10:00:58:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:00:58:elinks:INFO:	Disabling clock on downlink 0
10:00:58:elinks:INFO:	Disabling clock on downlink 1
10:00:58:elinks:INFO:	Disabling clock on downlink 2
10:00:58:elinks:INFO:	Disabling clock on downlink 3
10:00:58:elinks:INFO:	Disabling clock on downlink 4
10:00:58:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:00:58:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [3]
10:00:58:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:00:58:elinks:INFO:	Disabling clock on downlink 0
10:00:58:elinks:INFO:	Disabling clock on downlink 1
10:00:58:elinks:INFO:	Disabling clock on downlink 2
10:00:58:elinks:INFO:	Disabling clock on downlink 3
10:00:58:elinks:INFO:	Disabling clock on downlink 4
10:00:58:setup_element:INFO:	Checking SOS, encoding_mode: SOS
10:00:58:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [4]
10:00:59:setup_element:INFO:	Reassigning uplinks to uplinks which passed SOS detection
10:00:59:setup_element:INFO:	Scanning clock phase
10:00:59:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:00:59:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:00:59:setup_element:INFO:	Clock phase scan results for group 0, downlink 1
10:00:59:setup_element:INFO:	Eye window for uplink 0 : __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 1 : __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 2 : __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 3 : __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 4 : ____________________________________________________________________________XXXX
Clock Delay: 37
10:00:59:setup_element:INFO:	Eye window for uplink 5 : ____________________________________________________________________________XXXX
Clock Delay: 37
10:00:59:setup_element:INFO:	Eye window for uplink 6 : ___________________________________________________________________________XXX__
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 7 : ___________________________________________________________________________XXX__
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 8 : ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 9 : ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 10: ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 11: ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 12: ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 13: ________________________________________________________________________XXXXXX__
Clock Delay: 34
10:00:59:setup_element:INFO:	Eye window for uplink 14: __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Eye window for uplink 15: __________________________________________________________________________XXXXXX
Clock Delay: 36
10:00:59:setup_element:INFO:	Setting the clock phase to 35 for group 0, downlink 1
10:00:59:setup_element:INFO:	Scanning data phases
10:00:59:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:00:59:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:01:04:setup_element:INFO:	Data phase scan results for group 0, downlink 1
10:01:04:setup_element:INFO:	Eye window for uplink 0 : _______XXXXX____________________________
Data delay found: 29
10:01:04:setup_element:INFO:	Eye window for uplink 1 : __XXXXXX________________________________
Data delay found: 24
10:01:04:setup_element:INFO:	Eye window for uplink 2 : ____XXXXX_______________________________
Data delay found: 26
10:01:04:setup_element:INFO:	Eye window for uplink 3 : _XXXX___________________________________
Data delay found: 22
10:01:04:setup_element:INFO:	Eye window for uplink 4 : __XXXXX_________________________________
Data delay found: 24
10:01:04:setup_element:INFO:	Eye window for uplink 5 : XX____________________________________XX
Data delay found: 19
10:01:04:setup_element:INFO:	Eye window for uplink 6 : _________________________________XXXXX__
Data delay found: 15
10:01:04:setup_element:INFO:	Eye window for uplink 7 : ______________________________XXXX______
Data delay found: 11
10:01:04:setup_element:INFO:	Eye window for uplink 8 : __________________XXXXXX________________
Data delay found: 0
10:01:04:setup_element:INFO:	Eye window for uplink 9 : ________________________XXXX____________
Data delay found: 5
10:01:04:setup_element:INFO:	Eye window for uplink 10: ___________________XXXXXX_______________
Data delay found: 1
10:01:04:setup_element:INFO:	Eye window for uplink 11: ________________________XXXXX___________
Data delay found: 6
10:01:04:setup_element:INFO:	Eye window for uplink 12: ______________________XXXXX_____________
Data delay found: 4
10:01:04:setup_element:INFO:	Eye window for uplink 13: __________________________XXXX__________
Data delay found: 7
10:01:04:setup_element:INFO:	Eye window for uplink 14: _________________________XXXXX__________
Data delay found: 7
10:01:04:setup_element:INFO:	Eye window for uplink 15: ___________________________XXXXXX_______
Data delay found: 9
10:01:04:setup_element:INFO:	Setting the data phase to 29 for uplink 0
10:01:04:setup_element:INFO:	Setting the data phase to 24 for uplink 1
10:01:04:setup_element:INFO:	Setting the data phase to 26 for uplink 2
10:01:04:setup_element:INFO:	Setting the data phase to 22 for uplink 3
10:01:04:setup_element:INFO:	Setting the data phase to 24 for uplink 4
10:01:04:setup_element:INFO:	Setting the data phase to 19 for uplink 5
10:01:04:setup_element:INFO:	Setting the data phase to 15 for uplink 6
10:01:04:setup_element:INFO:	Setting the data phase to 11 for uplink 7
10:01:04:setup_element:INFO:	Setting the data phase to 0 for uplink 8
10:01:04:setup_element:INFO:	Setting the data phase to 5 for uplink 9
10:01:04:setup_element:INFO:	Setting the data phase to 1 for uplink 10
10:01:04:setup_element:INFO:	Setting the data phase to 6 for uplink 11
10:01:04:setup_element:INFO:	Setting the data phase to 4 for uplink 12
10:01:04:setup_element:INFO:	Setting the data phase to 7 for uplink 13
10:01:04:setup_element:INFO:	Setting the data phase to 7 for uplink 14
10:01:04:setup_element:INFO:	Setting the data phase to 9 for uplink 15
10:01:04:ST3_emu:ERROR:	[
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map: None
  Clock Phase Characteristic:
    Optimal Phase: 35
    Window Length: 72
    Eye Windows:
      Uplink  0: __________________________________________________________________________XXXXXX
      Uplink  1: __________________________________________________________________________XXXXXX
      Uplink  2: __________________________________________________________________________XXXXXX
      Uplink  3: __________________________________________________________________________XXXXXX
      Uplink  4: ____________________________________________________________________________XXXX
      Uplink  5: ____________________________________________________________________________XXXX
      Uplink  6: ___________________________________________________________________________XXX__
      Uplink  7: ___________________________________________________________________________XXX__
      Uplink  8: ________________________________________________________________________XXXXXX__
      Uplink  9: ________________________________________________________________________XXXXXX__
      Uplink 10: ________________________________________________________________________XXXXXX__
      Uplink 11: ________________________________________________________________________XXXXXX__
      Uplink 12: ________________________________________________________________________XXXXXX__
      Uplink 13: ________________________________________________________________________XXXXXX__
      Uplink 14: __________________________________________________________________________XXXXXX
      Uplink 15: __________________________________________________________________________XXXXXX
  Data phase characteristics:
    Uplink 0:
      Optimal Phase: 29
      Window Length: 35
      Eye Window: _______XXXXX____________________________
    Uplink 1:
      Optimal Phase: 24
      Window Length: 34
      Eye Window: __XXXXXX________________________________
    Uplink 2:
      Optimal Phase: 26
      Window Length: 35
      Eye Window: ____XXXXX_______________________________
    Uplink 3:
      Optimal Phase: 22
      Window Length: 36
      Eye Window: _XXXX___________________________________
    Uplink 4:
      Optimal Phase: 24
      Window Length: 35
      Eye Window: __XXXXX_________________________________
    Uplink 5:
      Optimal Phase: 19
      Window Length: 36
      Eye Window: XX____________________________________XX
    Uplink 6:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 7:
      Optimal Phase: 11
      Window Length: 36
      Eye Window: ______________________________XXXX______
    Uplink 8:
      Optimal Phase: 0
      Window Length: 34
      Eye Window: __________________XXXXXX________________
    Uplink 9:
      Optimal Phase: 5
      Window Length: 36
      Eye Window: ________________________XXXX____________
    Uplink 10:
      Optimal Phase: 1
      Window Length: 34
      Eye Window: ___________________XXXXXX_______________
    Uplink 11:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 12:
      Optimal Phase: 4
      Window Length: 35
      Eye Window: ______________________XXXXX_____________
    Uplink 13:
      Optimal Phase: 7
      Window Length: 36
      Eye Window: __________________________XXXX__________
    Uplink 14:
      Optimal Phase: 7
      Window Length: 35
      Eye Window: _________________________XXXXX__________
    Uplink 15:
      Optimal Phase: 9
      Window Length: 34
      Eye Window: ___________________________XXXXXX_______
]
10:01:04:setup_element:INFO:	Beginning SMX ASICs map scan
10:01:04:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:01:04:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:01:04:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
10:01:04:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
10:01:04:uplink:INFO:	Setting uplinks mask [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]
10:01:04:setup_element:INFO:	Adding ASIC 0x0, ASIC uplink 0, uplink 1
10:01:04:setup_element:INFO:	Adding ASIC 0x0, ASIC uplink 1, uplink 0
10:01:05:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 0, uplink 8
10:01:05:setup_element:INFO:	Adding ASIC 0x1, ASIC uplink 1, uplink 9
10:01:05:setup_element:INFO:	Adding ASIC 0x2, ASIC uplink 0, uplink 3
10:01:05:setup_element:INFO:	Adding ASIC 0x2, ASIC uplink 1, uplink 2
10:01:05:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 0, uplink 10
10:01:05:setup_element:INFO:	Adding ASIC 0x3, ASIC uplink 1, uplink 11
10:01:05:setup_element:INFO:	Adding ASIC 0x4, ASIC uplink 0, uplink 5
10:01:05:setup_element:INFO:	Adding ASIC 0x4, ASIC uplink 1, uplink 4
10:01:05:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 0, uplink 12
10:01:05:setup_element:INFO:	Adding ASIC 0x5, ASIC uplink 1, uplink 13
10:01:05:setup_element:INFO:	Adding ASIC 0x6, ASIC uplink 0, uplink 7
10:01:06:setup_element:INFO:	Adding ASIC 0x6, ASIC uplink 1, uplink 6
10:01:06:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 0, uplink 14
10:01:06:setup_element:INFO:	Adding ASIC 0x7, ASIC uplink 1, uplink 15
10:01:07:ST3_emu:ERROR:	
Setup Element:
  Group: 0
  Downlink: 1
  Uplinks: [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]
  ASICs Map:
    ASIC address 0x0: (ASIC uplink, uplink): (0, 1), (1, 0)
    ASIC address 0x1: (ASIC uplink, uplink): (0, 8), (1, 9)
    ASIC address 0x2: (ASIC uplink, uplink): (0, 3), (1, 2)
    ASIC address 0x3: (ASIC uplink, uplink): (0, 10), (1, 11)
    ASIC address 0x4: (ASIC uplink, uplink): (0, 5), (1, 4)
    ASIC address 0x5: (ASIC uplink, uplink): (0, 12), (1, 13)
    ASIC address 0x6: (ASIC uplink, uplink): (0, 7), (1, 6)
    ASIC address 0x7: (ASIC uplink, uplink): (0, 14), (1, 15)
  Clock Phase Characteristic:
    Optimal Phase: 35
    Window Length: 72
    Eye Windows:
      Uplink  0: __________________________________________________________________________XXXXXX
      Uplink  1: __________________________________________________________________________XXXXXX
      Uplink  2: __________________________________________________________________________XXXXXX
      Uplink  3: __________________________________________________________________________XXXXXX
      Uplink  4: ____________________________________________________________________________XXXX
      Uplink  5: ____________________________________________________________________________XXXX
      Uplink  6: ___________________________________________________________________________XXX__
      Uplink  7: ___________________________________________________________________________XXX__
      Uplink  8: ________________________________________________________________________XXXXXX__
      Uplink  9: ________________________________________________________________________XXXXXX__
      Uplink 10: ________________________________________________________________________XXXXXX__
      Uplink 11: ________________________________________________________________________XXXXXX__
      Uplink 12: ________________________________________________________________________XXXXXX__
      Uplink 13: ________________________________________________________________________XXXXXX__
      Uplink 14: __________________________________________________________________________XXXXXX
      Uplink 15: __________________________________________________________________________XXXXXX
  Data phase characteristics:
    Uplink 0:
      Optimal Phase: 29
      Window Length: 35
      Eye Window: _______XXXXX____________________________
    Uplink 1:
      Optimal Phase: 24
      Window Length: 34
      Eye Window: __XXXXXX________________________________
    Uplink 2:
      Optimal Phase: 26
      Window Length: 35
      Eye Window: ____XXXXX_______________________________
    Uplink 3:
      Optimal Phase: 22
      Window Length: 36
      Eye Window: _XXXX___________________________________
    Uplink 4:
      Optimal Phase: 24
      Window Length: 35
      Eye Window: __XXXXX_________________________________
    Uplink 5:
      Optimal Phase: 19
      Window Length: 36
      Eye Window: XX____________________________________XX
    Uplink 6:
      Optimal Phase: 15
      Window Length: 35
      Eye Window: _________________________________XXXXX__
    Uplink 7:
      Optimal Phase: 11
      Window Length: 36
      Eye Window: ______________________________XXXX______
    Uplink 8:
      Optimal Phase: 0
      Window Length: 34
      Eye Window: __________________XXXXXX________________
    Uplink 9:
      Optimal Phase: 5
      Window Length: 36
      Eye Window: ________________________XXXX____________
    Uplink 10:
      Optimal Phase: 1
      Window Length: 34
      Eye Window: ___________________XXXXXX_______________
    Uplink 11:
      Optimal Phase: 6
      Window Length: 35
      Eye Window: ________________________XXXXX___________
    Uplink 12:
      Optimal Phase: 4
      Window Length: 35
      Eye Window: ______________________XXXXX_____________
    Uplink 13:
      Optimal Phase: 7
      Window Length: 36
      Eye Window: __________________________XXXX__________
    Uplink 14:
      Optimal Phase: 7
      Window Length: 35
      Eye Window: _________________________XXXXX__________
    Uplink 15:
      Optimal Phase: 9
      Window Length: 34
      Eye Window: ___________________________XXXXXX_______

10:01:07:setup_element:INFO:	Performing Elink synchronization
10:01:07:master:INFO:	Setting encoding mode SOS for groups [0], downlinks [1]
10:01:07:master:INFO:	Setting encoding mode K.28.1 for groups [0], downlinks [1]
10:01:07:master:INFO:	Setting encoding mode EOS for groups [0], downlinks [1]
10:01:07:master:INFO:	Setting encoding mode FRAME for groups [0], downlinks [1]
10:01:07:setup_element:INFO:	Writing SMX Elink masks for group 0, downlink 1
10:01:07:uplink:INFO:	Enabling uplinks [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15]
10:01:07:ST3_emu:INFO:	Number of chips: 8
addr  |  upli  |  dwnli  |  grp |  uplinks | uplinks_map
   0  |   [0]   |  1  |  0  |     [1]      |   [(0, 1), (1, 0)] 
   1  |   [0]   |  1  |  0  |     [8]      |   [(0, 8), (1, 9)] 
   2  |   [0]   |  1  |  0  |     [3]      |   [(0, 3), (1, 2)] 
   3  |   [0]   |  1  |  0  |     [10]     |  [(0, 10), (1, 11)]
   4  |   [0]   |  1  |  0  |     [5]      |   [(0, 5), (1, 4)] 
   5  |   [0]   |  1  |  0  |     [12]     |  [(0, 12), (1, 13)]
   6  |   [0]   |  1  |  0  |     [7]      |   [(0, 7), (1, 6)] 
   7  |   [0]   |  1  |  0  |     [14]     |  [(0, 14), (1, 15)]
FEB type: A FEB_A: 1 FEB_B: 0
10:01:09:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
10:01:09:febtest:INFO:	01-00 | XA-000-08-003-000-000-075-01 |  37.7 | 1183.3
10:01:09:febtest:INFO:	08-01 | XA-000-08-003-000-000-057-13 |  44.1 | 1183.3
10:01:09:febtest:INFO:	03-02 | XA-000-08-003-000-000-076-01 |  63.2 | 1094.2
10:01:10:febtest:INFO:	10-03 | XA-000-08-003-000-000-060-13 |  40.9 | 1189.2
10:01:10:febtest:INFO:	05-04 | XA-000-08-003-000-000-080-06 |  37.7 | 1189.2
10:01:10:febtest:INFO:	12-05 | XA-000-08-003-000-000-058-13 |  66.4 | 1082.3
10:01:10:febtest:INFO:	07-06 | XA-000-08-003-000-000-086-06 |  50.4 | 1135.9
10:01:10:febtest:INFO:	14-07 | XA-000-08-003-000-000-064-01 |  31.4 | 1212.7
10:01:10:ST3_smx:INFO:	Configuring SMX FAST
10:01:13:ST3_smx:INFO:	chip: 1-0 	 44.073563 C 	 1153.732915 mV
10:01:13:ST3_smx:INFO:		Electrons
10:01:13:ST3_smx:INFO:	# loops 0
10:01:15:ST3_smx:INFO:	# loops 1
10:01:18:ST3_smx:INFO:	# loops 2
10:01:20:ST3_smx:INFO:	Total # of broken channels: 0
10:01:20:ST3_smx:INFO:	List of broken channels: []
10:01:20:ST3_smx:INFO:	Total # of broken channels: 0
10:01:20:ST3_smx:INFO:	List of broken channels: []
10:01:21:ST3_smx:INFO:	Configuring SMX FAST
10:01:24:ST3_smx:INFO:	chip: 8-1 	 50.430383 C 	 1159.654860 mV
10:01:24:ST3_smx:INFO:		Electrons
10:01:24:ST3_smx:INFO:	# loops 0
10:01:26:ST3_smx:INFO:	# loops 1
10:01:28:ST3_smx:INFO:	# loops 2
10:01:30:ST3_smx:INFO:	Total # of broken channels: 0
10:01:30:ST3_smx:INFO:	List of broken channels: []
10:01:30:ST3_smx:INFO:	Total # of broken channels: 8
10:01:30:ST3_smx:INFO:	List of broken channels: [1, 3, 5, 7, 9, 11, 13, 15]
10:01:31:ST3_smx:INFO:	Configuring SMX FAST
10:01:33:ST3_smx:INFO:	chip: 3-2 	 63.173842 C 	 1100.211760 mV
10:01:33:ST3_smx:INFO:		Electrons
10:01:33:ST3_smx:INFO:	# loops 0
10:01:35:ST3_smx:INFO:	# loops 1
10:01:38:ST3_smx:INFO:	# loops 2
10:01:40:ST3_smx:INFO:	Total # of broken channels: 0
10:01:40:ST3_smx:INFO:	List of broken channels: []
10:01:40:ST3_smx:INFO:	Total # of broken channels: 4
10:01:40:ST3_smx:INFO:	List of broken channels: [1, 3, 5, 7]
10:01:41:ST3_smx:INFO:	Configuring SMX FAST
10:01:43:ST3_smx:INFO:	chip: 10-3 	 40.898880 C 	 1200.969315 mV
10:01:43:ST3_smx:INFO:		Electrons
10:01:43:ST3_smx:INFO:	# loops 0
10:01:45:ST3_smx:INFO:	# loops 1
10:01:47:ST3_smx:INFO:	# loops 2
10:01:49:ST3_smx:INFO:	Total # of broken channels: 0
10:01:49:ST3_smx:INFO:	List of broken channels: []
10:01:49:ST3_smx:INFO:	Total # of broken channels: 2
10:01:49:ST3_smx:INFO:	List of broken channels: [3, 5]
10:01:50:ST3_smx:INFO:	Configuring SMX FAST
10:01:53:ST3_smx:INFO:	chip: 5-4 	 44.073563 C 	 1177.390875 mV
10:01:53:ST3_smx:INFO:		Electrons
10:01:53:ST3_smx:INFO:	# loops 0
10:01:55:ST3_smx:INFO:	# loops 1
10:01:57:ST3_smx:INFO:	# loops 2
10:01:59:ST3_smx:INFO:	Total # of broken channels: 0
10:01:59:ST3_smx:INFO:	List of broken channels: []
10:01:59:ST3_smx:INFO:	Total # of broken channels: 1
10:01:59:ST3_smx:INFO:	List of broken channels: [0]
10:02:00:ST3_smx:INFO:	Configuring SMX FAST
10:02:03:ST3_smx:INFO:	chip: 12-5 	 63.173842 C 	 1118.096875 mV
10:02:03:ST3_smx:INFO:		Electrons
10:02:03:ST3_smx:INFO:	# loops 0
10:02:05:ST3_smx:INFO:	# loops 1
10:02:07:ST3_smx:INFO:	# loops 2
10:02:09:ST3_smx:INFO:	Total # of broken channels: 0
10:02:09:ST3_smx:INFO:	List of broken channels: []
10:02:09:ST3_smx:INFO:	Total # of broken channels: 14
10:02:09:ST3_smx:INFO:	List of broken channels: [95, 97, 99, 103, 105, 107, 109, 111, 113, 115, 117, 119, 121, 123]
10:02:10:ST3_smx:INFO:	Configuring SMX FAST
10:02:12:ST3_smx:INFO:	chip: 7-6 	 59.984250 C 	 1118.096875 mV
10:02:12:ST3_smx:INFO:		Electrons
10:02:13:ST3_smx:INFO:	# loops 0
10:02:15:ST3_smx:INFO:	# loops 1
10:02:17:ST3_smx:INFO:	# loops 2
10:02:19:ST3_smx:INFO:	Total # of broken channels: 0
10:02:19:ST3_smx:INFO:	List of broken channels: []
10:02:19:ST3_smx:INFO:	Total # of broken channels: 0
10:02:19:ST3_smx:INFO:	List of broken channels: []
10:02:20:ST3_smx:INFO:	Configuring SMX FAST
10:02:22:ST3_smx:INFO:	chip: 14-7 	 37.726682 C 	 1200.969315 mV
10:02:22:ST3_smx:INFO:		Electrons
10:02:22:ST3_smx:INFO:	# loops 0
10:02:24:ST3_smx:INFO:	# loops 1
10:02:26:ST3_smx:INFO:	# loops 2
10:02:28:ST3_smx:INFO:	Total # of broken channels: 0
10:02:28:ST3_smx:INFO:	List of broken channels: []
10:02:28:ST3_smx:INFO:	Total # of broken channels: 0
10:02:28:ST3_smx:INFO:	List of broken channels: []
10:02:29:febtest:INFO:	_Addr_|___________ASIC-ID_____________|_T_[C]_|_Vddm_[mV]_
10:02:29:febtest:INFO:	01-00 | XA-000-08-003-000-000-075-01 |  47.3 | 1159.7
10:02:30:febtest:INFO:	08-01 | XA-000-08-003-000-000-057-13 |  53.6 | 1159.7
10:02:30:febtest:INFO:	03-02 | XA-000-08-003-000-000-076-01 |  66.4 | 1100.2
10:02:30:febtest:INFO:	10-03 | XA-000-08-003-000-000-060-13 |  40.9 | 1201.0
10:02:30:febtest:INFO:	05-04 | XA-000-08-003-000-000-080-06 |  47.3 | 1177.4
10:02:30:febtest:INFO:	12-05 | XA-000-08-003-000-000-058-13 |  63.2 | 1118.1
10:02:31:febtest:INFO:	07-06 | XA-000-08-003-000-000-086-06 |  60.0 | 1118.1
10:02:31:febtest:INFO:	14-07 | XA-000-08-003-000-000-064-01 |  40.9 | 1201.0
############################################################
#                   S U M M A R Y                          #
############################################################
TEST_NAME : FEB-Microcable
TEST_DATE : 24_06_11-10_00_55
OPERATOR  : Henrik; 
SITE      : KIT
SETUP     : KIT_TEST_SETUP_1
Set-ID    : 
---------------------------------------
MODULE_NAME : 
FEB_SN : 3030
FEB_TYPE : 8.2
FEB_UPLINKS : 2
FEB_A : 1
FEB_B : 0
---------------------------------------
---------------------------------------
VI_before_Init : ['2.450', '1.6080', '1.850', '2.2230', '0.000', '0.0000', '0.000', '0.0000']
VI_after__Init : ['2.450', '1.9940', '1.850', '0.4378', '0.000', '0.0000', '0.000', '0.0000']
VI_at__the_End : ['2.450', '1.9900', '1.850', '0.3180', '0.000', '0.0000', '0.000', '0.0000']