XA-000-08-001-064-042-056-00 19.10.23 08:05:43
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2023_10_19-08_05_43 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0000L000-M000 | side-P | index: (8/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-001-064-042-056-00 | FUSED_ID : 6359364698915382144 IC_TEMP : 8.55 | VDDM : 1129.74 | AUX_INT : 0.00 | CsaBias : 162.59 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 1.99388e-05 / 1 ADC_P0 : 0.00000e+00 ± 4.46529e-03 ADC_P1 : 7.49077e-03 ± 7.43154e-05 ADC_P2 : -4.56019e-06 ± 4.26284e-07 CSA_Chi2/NDF : 2.98840e-05 / 1 CSA_P0 : 6.36417e-02 ± 2.05756e-03 CSA_P1 : 8.88876e-03 ± 1.52572e-04 CSA_P2 : -2.03263e-05 ± 2.32860e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.201', '0.5385', '1.800', '0.1176', '1.801', '0.0994', '6.998', '0.6915'] VI_after__Init : ['1.200', '0.5299', '1.800', '0.1439', '1.800', '0.0978', '7.000', '0.6933'] VI_at__the_End : ['1.200', '0.5404', '1.800', '0.1477', '1.800', '0.0719', '7.000', '0.6944']