XA-000-08-003-000-001-004-09 15.11.23 12:09:08
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2023_11_15-12_09_08 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0516L035-M004 | side-P | index: (2/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-001-004-09 | FUSED_ID : 6359364699384975433 IC_TEMP : 20.67 | VDDM : 1116.85 | AUX_INT : 0.00 | CsaBias : 185.16 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 6.77843e-05 / 2 ADC_P0 : 0.00000e+00 ± 5.82170e-03 ADC_P1 : 7.83056e-03 ± 1.02276e-04 ADC_P2 : -4.82189e-06 ± 6.16454e-07 CSA_Chi2/NDF : 4.69038e-05 / 2 CSA_P0 : 6.66667e-02 ± 2.57773e-03 CSA_P1 : 9.18651e-03 ± 1.91144e-04 CSA_P2 : -2.18989e-05 ± 2.91729e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.3178', '1.800', '0.1673', '1.800', '0.1309', '7.001', '0.6999'] VI_after__Init : ['1.200', '0.3184', '1.800', '0.1658', '1.800', '0.1289', '7.000', '0.7007'] VI_at__the_End : ['1.200', '0.5560', '1.800', '0.1745', '1.800', '0.0739', '7.000', '0.7012']