XA-000-08-003-000-002-216-15 12.10.23 08:26:18
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2023_10_12-08_26_18 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0528L036-M002 | side-N | index: (6/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-002-216-15 | FUSED_ID : 6359364699384982927 IC_TEMP : 9.17 | VDDM : 1119.99 | AUX_INT : 0.00 | CsaBias : 101.34 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 2.69187e-06 / 0 ADC_P0 : 0.00000e+00 ± 1.00000e+00 ADC_P1 : 7.85916e-03 ± 2.61319e-02 ADC_P2 : -4.87723e-06 ± 1.53243e-04 CSA_Chi2/NDF : 8.09258e-05 / 0 CSA_P0 : 6.24875e-02 ± 3.38592e-03 CSA_P1 : 9.92176e-03 ± 2.51073e-04 CSA_P2 : -4.08363e-05 ± 3.83194e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.0313', '1.800', '0.1417', '1.800', '0.0729', '7.000', '0.6983'] VI_after__Init : ['1.200', '0.0337', '1.800', '0.1418', '1.800', '0.0730', '7.000', '0.6980'] VI_at__the_End : ['1.200', '0.5200', '1.800', '0.1652', '1.800', '0.0737', '7.000', '0.6984']