XA-000-08-003-000-002-230-06 19.10.23 08:21:53
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2023_10_19-08_21_53 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0000L000-M000 | side-P | index: (2/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-002-230-06 | FUSED_ID : 6359364699384983142 IC_TEMP : 19.02 | VDDM : 1124.95 | AUX_INT : 0.00 | CsaBias : 185.06 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 2.33951e-05 / 1 ADC_P0 : 0.00000e+00 ± 4.83684e-03 ADC_P1 : 7.24350e-03 ± 7.53708e-05 ADC_P2 : -4.83943e-06 ± 4.09031e-07 CSA_Chi2/NDF : 3.36791e-05 / 1 CSA_P0 : 6.69875e-02 ± 2.18431e-03 CSA_P1 : 9.09583e-03 ± 1.61971e-04 CSA_P2 : -2.39638e-05 ± 2.47204e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.0353', '1.800', '0.1246', '1.800', '0.0430', '7.000', '0.7017'] VI_after__Init : ['1.200', '0.0353', '1.800', '0.1218', '1.800', '0.0430', '7.000', '0.7019'] VI_at__the_End : ['1.200', '0.5424', '1.800', '0.1621', '1.800', '0.0734', '7.000', '0.7018']