XA-000-08-003-000-003-113-06 15.12.23 10:48:12
ADC4
SMX_7
CSA
Info
TEST_NAME : Microcable
TEST_DATE : 2023_12_15-10_48_12
OPERATOR : Alois Alzheimer
SITE : KIT
SETUP : KIT_TEST_SETUP_1
Set-ID : 0745L040-M000 | side-P | index: (8/8)
---------------------------------------
---------------------------------------
ASIC_CONFIG_PARAMETERS
HW_ADDR : 0x7 | VERS_NO : 2.2
ASIC_ID : XA-000-08-003-000-003-113-06 | FUSED_ID : 6359364699384985366
IC_TEMP : 28.87 | VDDM : 1130.33 | AUX_INT : 0.00 | CsaBias : 472.72
CONF_FAIL_REG : 0
CSA_BIAS : 15
THR2_GLB : 30
ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122
ADC_Chi2/NDF : 3.99267e-05 / 2
ADC_P0 : 0.00000e+00 ± 4.46803e-03
ADC_P1 : 7.06158e-03 ± 7.30204e-05
ADC_P2 : -3.05130e-06 ± 4.09182e-07
CSA_Chi2/NDF : 1.76591e-05 / 2
CSA_P0 : 2.80976e-02 ± 4.08214e-03
CSA_P1 : 8.83704e-03 ± 3.11981e-04
CSA_P2 : -1.86540e-05 ± 4.71704e-06
---------------------------------------
N_BROKEN_DISC : 0 | N_BROKEN_FAST : []
N_BROKEN_CABLE : 0
LIST_OF_BROKEN_CABLES : []
---------------------------------------
VI_before_Init : ['1.200', '0.3988', '1.800', '0.0896', '1.800', '0.0826', '7.000', '0.6896']
VI_after__Init : ['1.200', '0.3972', '1.800', '0.1354', '1.800', '0.0821', '7.000', '0.6926']
VI_at__the_End : ['1.200', '0.5137', '1.800', '0.1438', '1.800', '0.0734', '7.000', '0.6941']