XA-000-08-003-000-003-230-11 22.01.24 08:40:22
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_22-08_40_22 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0826L057-M000 | side-P | index: (8/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-003-230-11 | FUSED_ID : 6359364699384987243 IC_TEMP : 18.58 | VDDM : 1050.15 | AUX_INT : 0.00 | CsaBias : 84.25 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 8.87166e-05 / 2 ADC_P0 : 0.00000e+00 ± 6.66020e-03 ADC_P1 : 7.06415e-03 ± 1.07220e-04 ADC_P2 : -3.59089e-06 ± 5.90164e-07 CSA_Chi2/NDF : 5.03664e-05 / 2 CSA_P0 : 2.59152e-02 ± 6.89404e-03 CSA_P1 : 9.85792e-03 ± 5.26883e-04 CSA_P2 : -4.08419e-05 ± 7.96627e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.3750', '1.800', '0.1111', '1.800', '0.1266', '7.000', '0.6978'] VI_after__Init : ['1.200', '0.3716', '1.800', '0.1099', '1.800', '0.1654', '7.000', '0.7003'] VI_at__the_End : ['1.200', '0.4821', '1.800', '0.0744', '1.800', '0.1708', '7.000', '0.7007']