XA-000-08-003-000-003-233-11 22.01.24 08:29:26
ADC4
SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_22-08_29_26 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0828L057-M001 | side-N | index: (6/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-003-233-11 | FUSED_ID : 6359364699384987291 IC_TEMP : 45.27 | VDDM : 1068.37 | AUX_INT : 0.00 | CsaBias : 160.84 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 1.53674e-05 / 2 ADC_P0 : 0.00000e+00 ± 2.77195e-03 ADC_P1 : 7.06494e-03 ± 4.52707e-05 ADC_P2 : -3.13206e-06 ± 2.53158e-07 CSA_Chi2/NDF : 8.00238e-07 / 2 CSA_P0 : 2.80124e-02 ± 8.68986e-04 CSA_P1 : 8.84980e-03 ± 6.64131e-05 CSA_P2 : -2.53267e-05 ± 1.00414e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.201', '0.2842', '1.800', '0.1021', '1.800', '0.4841', '6.999', '0.6937'] VI_after__Init : ['1.200', '0.2848', '1.800', '0.1005', '1.800', '0.5043', '7.000', '0.6970'] VI_at__the_End : ['1.200', '0.4842', '1.800', '0.0732', '1.800', '0.5107', '7.000', '0.6975']