XA-000-08-003-000-004-029-05 22.11.23 14:56:06
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2023_11_22-14_56_06 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0736L039-M003 | side-P | index: (5/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-004-029-05 | FUSED_ID : 6359364699384988117 IC_TEMP : 22.45 | VDDM : 1151.28 | AUX_INT : 0.00 | CsaBias : 327.88 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 5.02450e-05 / 2 ADC_P0 : 0.00000e+00 ± 5.01223e-03 ADC_P1 : 7.27314e-03 ± 8.50515e-05 ADC_P2 : -3.16074e-06 ± 4.92183e-07 CSA_Chi2/NDF : 4.10819e-05 / 2 CSA_P0 : 6.52833e-02 ± 2.41245e-03 CSA_P1 : 8.78280e-03 ± 1.78888e-04 CSA_P2 : -1.78424e-05 ± 2.73024e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.1147', '1.800', '0.0945', '1.800', '0.0790', '7.000', '0.6980'] VI_after__Init : ['1.200', '0.1178', '1.801', '0.1349', '1.800', '0.0790', '7.000', '0.7010'] VI_at__the_End : ['1.200', '0.5500', '1.800', '0.1620', '1.800', '0.0738', '7.000', '0.7014']