XA-000-08-003-000-004-076-07 18.01.24 14:13:53
ADC4
SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_18-14_13_53 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0832L057-M003 | side-P | index: (4/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-004-076-07 | FUSED_ID : 6359364699384988871 IC_TEMP : 12.47 | VDDM : 1114.02 | AUX_INT : 0.00 | CsaBias : 115.56 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 5.02450e-05 / 2 ADC_P0 : 0.00000e+00 ± 5.01223e-03 ADC_P1 : 7.27314e-03 ± 8.50515e-05 ADC_P2 : -3.16074e-06 ± 4.92183e-07 CSA_Chi2/NDF : 2.46282e-05 / 2 CSA_P0 : 2.67219e-02 ± 4.82080e-03 CSA_P1 : 9.72176e-03 ± 3.68434e-04 CSA_P2 : -3.57621e-05 ± 5.57058e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.2619', '1.800', '0.1036', '1.800', '0.1545', '6.998', '0.6993'] VI_after__Init : ['1.200', '0.2641', '1.800', '0.1029', '1.800', '0.1543', '7.000', '0.7003'] VI_at__the_End : ['1.200', '0.4954', '1.800', '0.0732', '1.800', '0.1644', '7.000', '0.7002']