XA-000-08-003-000-004-090-00 16.01.24 07:43:07
ADC4
SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_16-07_43_07 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0831L057-M003 | side-N | index: (5/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-004-090-00 | FUSED_ID : 6359364699384989088 IC_TEMP : -4.53 | VDDM : 1121.36 | AUX_INT : 0.00 | CsaBias : 110.85 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 3.15512e-05 / 2 ADC_P0 : 0.00000e+00 ± 3.97185e-03 ADC_P1 : 7.45306e-03 ± 6.66283e-05 ADC_P2 : -4.20419e-06 ± 3.84240e-07 CSA_Chi2/NDF : 3.74034e-05 / 2 CSA_P0 : 2.61481e-02 ± 5.94099e-03 CSA_P1 : 9.36126e-03 ± 4.54046e-04 CSA_P2 : -3.40471e-05 ± 6.86500e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.1432', '1.800', '0.0889', '1.800', '0.1480', '7.000', '0.7015'] VI_after__Init : ['1.200', '0.1448', '1.800', '0.0892', '1.800', '0.1464', '7.000', '0.7024'] VI_at__the_End : ['1.200', '0.4788', '1.800', '0.0702', '1.800', '0.1712', '7.000', '0.7024']