XA-000-08-003-000-004-114-14 11.01.24 12:15:03
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_11-12_15_03 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0829L057-M002 | side-P | index: (3/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-004-114-14 | FUSED_ID : 6359364699384989486 IC_TEMP : 25.57 | VDDM : 1085.77 | AUX_INT : 0.00 | CsaBias : 116.11 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 3.86158e-05 / 2 ADC_P0 : 0.00000e+00 ± 4.39408e-03 ADC_P1 : 7.31381e-03 ± 7.39557e-05 ADC_P2 : -3.53983e-06 ± 4.25693e-07 CSA_Chi2/NDF : 8.12266e-06 / 2 CSA_P0 : 2.73234e-02 ± 2.76855e-03 CSA_P1 : 9.63284e-03 ± 2.11589e-04 CSA_P2 : -3.32438e-05 ± 3.19914e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.200', '0.3677', '1.801', '0.1088', '1.800', '0.1587', '7.000', '0.7011'] VI_after__Init : ['1.200', '0.3701', '1.800', '0.1077', '1.800', '0.1583', '7.000', '0.7023'] VI_at__the_End : ['1.200', '0.5011', '1.800', '0.0745', '1.800', '0.1670', '7.000', '0.7021']