XA-000-08-003-000-004-157-15 24.01.24 12:02:45
ADC4
SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_24-12_02_45 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0705L039-M000 | side-N | index: (1/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-004-157-15 | FUSED_ID : 6359364699384990175 IC_TEMP : 28.23 | VDDM : 1088.26 | AUX_INT : 0.00 | CsaBias : 135.49 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 0.00000e+00 / 0 ADC_P0 : 0.00000e+00 ± 1.00000e-03 ADC_P1 : 6.82400e-03 ± 1.00000e-03 ADC_P2 : -2.48500e-06 ± 1.00000e-05 CSA_Chi2/NDF : 1.04762e-06 / 0 CSA_P0 : 2.68570e-02 ± 9.94273e-04 CSA_P1 : 9.29106e-03 ± 7.59882e-05 CSA_P2 : -2.79157e-05 ± 1.14891e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.199', '0.3257', '1.801', '0.0975', '1.800', '0.0977', '6.999', '0.7001'] VI_after__Init : ['1.200', '0.3302', '1.800', '0.0967', '1.800', '0.1484', '7.000', '0.7037'] VI_at__the_End : ['1.200', '0.5009', '1.800', '0.0726', '1.800', '0.1629', '7.000', '0.7036']