XA-000-08-003-000-005-045-01 26.01.24 08:06:08
ADC4
SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 2024_01_26-08_06_08 OPERATOR : Alois Alzheimer SITE : KIT SETUP : KIT_TEST_SETUP_1 Set-ID : 0713L039-M001 | side-N | index: (8/8) --------------------------------------- --------------------------------------- ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-08-003-000-005-045-01 | FUSED_ID : 6359364699384992465 IC_TEMP : 53.61 | VDDM : 998.02 | AUX_INT : 0.00 | CsaBias : 115.29 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 0.00000e+00 / 0 ADC_P0 : 0.00000e+00 ± 1.00000e-03 ADC_P1 : 6.82400e-03 ± 1.00000e-03 ADC_P2 : -2.48500e-06 ± 1.00000e-05 CSA_Chi2/NDF : 1.24192e-06 / 0 CSA_P0 : 2.78354e-02 ± 1.08255e-03 CSA_P1 : 9.13548e-03 ± 8.27352e-05 CSA_P2 : -2.39246e-05 ± 1.25092e-06 --------------------------------------- N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] --------------------------------------- VI_before_Init : ['1.201', '0.2976', '1.800', '0.0860', '1.800', '0.1140', '6.998', '0.6894'] VI_after__Init : ['1.200', '0.2977', '1.800', '0.0837', '1.800', '0.1537', '7.000', '0.6918'] VI_at__the_End : ['1.200', '0.5077', '1.800', '0.0740', '1.800', '0.1696', '7.000', '0.6921']