XA-000-09-004-002-005-005-06 05.12.24 09:11:08
ADC4

SMX_7

CSA

Report.txt
TEST_NAME : Microcable TEST_DATE : 24_12_05-09_11_08 OPERATOR : Henrik; SITE : KIT | SETUP : KIT_TEST_SETUP_1 ------------------------------------------------------------ ------------------------------------------------------------ ASIC_CONFIG_PARAMETERS HW_ADDR : 0x7 | VERS_NO : 2.2 ASIC_ID : XA-000-09-004-002-005-005-06 | FUSED_ID : 6359364768375001174 IC_TEMP : 6.33 | VDDM : 1097.76 | AUX_INT : -1.09 | CsaBias : 107.40 CONF_FAIL_REG : 0 CSA_BIAS : 15 THR2_GLB : 30 ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122 ADC_Chi2/NDF : 2.02131e-27 / 0 ADC_P0 : -1.08696e-03 ± 3.94524e+01 ADC_P1 : 7.81031e-03 ± 5.29927e-01 ADC_P2 : -4.38289e-06 ± 1.72777e-03 CSA_Chi2/NDF : 1.86103e-04 / 0 CSA_P0 : 3.96125e-02 ± 5.13465e-03 CSA_P1 : 9.68512e-03 ± 3.80744e-04 CSA_P2 : -3.57363e-05 ± 5.81102e-06 ------------------------------------------------------------ Set-ID : 0784L017-M002 | index: (1/8) N_BROKEN_DISC : 0 | N_BROKEN_FAST : [] N_BROKEN_CABLE : 0 LIST_OF_BROKEN_CABLES : [] ------------------------------------------------------------ VI_before_Init : ['1.200', '0.3758', '1.800', '0.1715', '1.800', '0.0833', '7.000', '0.6990'] VI_after__Init : ['1.200', '0.3835', '1.800', '0.1705', '1.800', '0.0831', '7.000', '0.7000'] VI_at__the_End : ['1.200', '0.5008', '1.800', '0.1385', '1.800', '0.0963', '7.000', '0.7003']