XA-000-09-004-006-007-024-09    20.09.24 10:12:56

ADC4
cADCscan.png
SMX_7
SMX_7.png
CSA
cCSAscan.png
Report.txt
            TEST_NAME : Microcable
TEST_DATE : 24_09_20-10_12_56
OPERATOR  : Alois Alzheimer
SITE : KIT | SETUP : KIT_TEST_SETUP_1
------------------------------------------------------------
------------------------------------------------------------
ASIC_CONFIG_PARAMETERS
  HW_ADDR : 0x7 | VERS_NO : 2.2
  ASIC_ID : XA-000-09-004-006-007-024-09 | FUSED_ID : 6359364768379203977
  IC_TEMP :    8.03 | VDDM : 1063.62 | AUX_INT :    0.00 | CsaBias :   78.07
  CONF_FAIL_REG : 0
  CSA_BIAS : 15
  THR2_GLB : 30
  ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122
  ADC_Chi2/NDF : 5.52563e-05 / 2
  ADC_P0  : 0.00000e+00 ± 5.25625e-03
  ADC_P1  : 7.86082e-03 ± 9.06592e-05
  ADC_P2  : -5.41055e-06 ± 5.39677e-07
  CSA_Chi2/NDF : 4.33423e-03 / 2
  CSA_P0  : 2.75167e-02 ± 2.47793e-02
  CSA_P1  : 6.80357e-03 ± 1.83743e-03
  CSA_P2  : 1.19195e-05 ± 2.80434e-05
------------------------------------------------------------
Set-ID    : 0734L039-M003 | side-P | index: (5/8)
N_BROKEN_DISC :  0 | N_BROKEN_FAST :  []
N_BROKEN_CABLE : 0
LIST_OF_BROKEN_CABLES : []
------------------------------------------------------------
VI_before_Init : ['1.199', '0.2496', '1.801', '0.1156', '1.800', '0.0811', '7.001', '0.7003']
VI_after__Init : ['1.200', '0.2170', '1.800', '0.1156', '1.800', '0.0805', '7.000', '0.7015']
VI_at__the_End : ['1.200', '0.4743', '1.800', '0.1375', '1.800', '0.0946', '7.000', '0.7016']