XA-000-09-004-019-009-017-12 04.06.25 14:54:47
ADC4
SMX_7
CSA
Info
TEST_NAME : Microcable
TEST_DATE : 25_06_04-14_54_47
OPERATOR : Alois Alzheimer
SITE : KIT | SETUP : KIT_TEST_SETUP_1
------------------------------------------------------------
------------------------------------------------------------
ASIC_CONFIG_PARAMETERS
HW_ADDR : 0x7 | VERS_NO : 2.2
ASIC_ID : XA-000-09-004-019-009-017-12 | FUSED_ID : 6359364768392843548
IC_TEMP : -9.07 | VDDM : 1102.91 | AUX_INT : 74.48 | CsaBias : 154.99
CONF_FAIL_REG : 0
CSA_BIAS : 15
THR2_GLB : 30
ADC_VREF_P : 58 | ADC_VREF_N : 30 | ADC_VREF_T : 128 | ADC_VREF_TR : 122
ADC_Chi2/NDF : 1.14386e-27 / 0
ADC_P0 : 7.44758e-02 ± 3.63390e+01
ADC_P1 : 7.35282e-03 ± 5.09212e-01
ADC_P2 : -3.02419e-06 ± 1.72777e-03
CSA_Chi2/NDF : 1.84283e-04 / 0
CSA_P0 : 4.30625e-02 ± 5.10948e-03
CSA_P1 : 9.89702e-03 ± 3.78878e-04
CSA_P2 : -4.26146e-05 ± 5.78254e-06
------------------------------------------------------------
Set-ID : 0900L059-M000 | side-P | index: (7/8)
N_BROKEN_DISC : 0 | N_BROKEN_FAST : []
N_BROKEN_CABLE : 0
LIST_OF_BROKEN_CABLES : []
------------------------------------------------------------
VI_before_Init : ['1.200', '0.2540', '1.800', '0.1257', '1.800', '0.0421', '7.000', '0.6923']
VI_after__Init : ['1.200', '0.2767', '1.800', '0.1264', '1.800', '0.0827', '7.000', '0.6969']
VI_at__the_End : ['1.200', '0.4902', '1.800', '0.1382', '1.800', '0.0978', '7.000', '0.6990']