FEB_A: 1217 FEB_B: 2212

-- Last status: 2025-03-20 09:00 [ Tested in Hk.Hl. ]


History of statuses:


Comments:

  • 2025-03-18 15:26 : < Lady CollazoSanchez > ( Dry out and rearranging of the microcables solved the breakdown )
  • 2025-02-13 14:25 : < Johann Heuser > ( B but required A )
  • 2025-02-13 13:37 : < Johann Heuser > ( presented by Anju on 12.02.2025 --> breakdown at > 350 V --> maybe class B (from A) )
  • 2025-02-11 11:30 : < Anju Sharma > ( Sharp breakdown at 370V )
  • 2025-02-11 11:29 : < Anju Sharma > ( Sharp breakdown at 370V )
  • 2025-02-11 11:28 : < Anju Sharma > ( Sharp breakdown at 370V )
  • 2025-02-11 11:27 : < Anju Sharma > ( Sharp breakdown at 375V (Optical grade A) )

Change Module Status:

Ladder: L8UL201022
Module: M8UL2T2010222B2
Sensor: 18054
Status: Tested in Hk.Hl.
OR/AND