The GICO output always starts by listing the corresponding input file.
The second portion of the output contains a compilation of the source-
and particle-definitions and a detailed
description of the optical system under consideration.
In front and in back of each drift distance the
floor coordinates U,V are listed together with the angle of the
beam direction W. Note that the first sector field is always assumed to
deflect to the right, i.e. towards negative V-values.
At any position zi, corresponding to the position zi in the input
file, the following effects can be initiated:
KPII