Link to ladder: L0DL000150
Module [ Site: GSI] versions: M0DL0T2001502A2 |
QR pdf
-- Last status: 2026-03-30 13:13 [ Tested Uplinks ]
Desired grade: A
History of statuses:
Comments:
- 2026-03-30 13:13 { Kerstin Schuenemann } ( ODI all ok )
- 2026-03-18 10:59 { Christian Schmidt } ( ODI test still missing, agreed with Kerstin to set to tested in HH )
- 2026-03-16 13:42 { Christian Schmidt } ( ODI test still missing )
- 2026-03-12 13:47 { Johann Heuser } ( IV and long-term bias test passed )
- 2026-03-09 07:32 { Uli Frankenfeld } ( done: : long-term IV test )
- 2026-02-25 15:32 { Johann Heuser } ( send to long-term IV test )
- 2026-02-25 10:43 { Johann Heuser } ( central module of grade A required, has high sensor current -- rebuild the module )
- 2026-02-16 13:09 { Kerstin Schuenemann } ( ODI all ok )
- 2026-02-05 22:37 { Anju Sharma } ( Slow breakdown at 425V, desired grade is A (500V). Current at EOL is 42microA. )
- 2026-02-05 22:37 { Anju Sharma } ( Slow breakdown at 425V, desired grade is A (500V). Current at EOL is 42microA. )
- 2026-01-13 20:44 { Anju Sharma } ( Breakdown at 425V )
Workflow
No documents uploaded yet.
⇧ Top
Change Module Status:
Ladder: L0DL000150
Module: M0DL0T2001502A2
Sensor: 13323
Status: Tested Uplinks