Link to ladder: L0DR100009


Module [ Site: GSI] versions: M0DR1T2000092B2 | QR pdf

-- Last status: 2026-03-30 13:03 [ Tested Uplinks ]


Desired grade: A


Link to Heck Halle Module Test Page


History of statuses:


Comments:

  • 2026-03-30 13:03 { Kerstin Schuenemann } ( ODI all ok )
  • 2026-03-18 11:04 { Christian Schmidt } ( ODI test still missing )
  • 2026-03-16 13:38 { Christian Schmidt } ( ODI Test still missing )
  • 2026-03-12 13:32 { Johann Heuser } ( IV curve passed test. EoL current 12 uA. )
  • 2026-03-09 07:31 { Uli Frankenfeld } ( Long term bias@EoL HV test in dedicated test stand started on 6.3. )
  • 2026-03-03 11:30 { Johann Heuser } ( long-term biassing shows promising lowering of currents from 20 to 11 microamps over ~42 hours, a second test ~ 20 hours with currents reducing from 20 to 14 microamps. Suggestion to run the long-term test longer, a few days. Needs a dedicated test stand as the current test stand is also needed for single-IV curves during ladder assembly. )
  • 2026-03-02 04:55 { Uli Frankenfeld } ( done: long-term IV test )
  • 2026-02-25 15:29 { Johann Heuser } ( send to long-term IV test )
  • 2026-02-25 11:57 { Anju Sharma } ( Slowbreakdown starting at 200V and reaching E0L (500V) at 45 micro )
  • 2026-01-13 20:38 { Anju Sharma } ( Slowbreakdown starting at 200V and reaching EOL (500V) at 45 micro A )
  • 2025-10-07 09:17 { Uli Frankenfeld } ( fix DB )

No documents uploaded yet.


⇧ Top

Change Module Status:

Ladder: L0DR100009
Module: M0DR1T2000092B2
Sensor: 17062
Status: Tested Uplinks
OR/AND