Link to ladder: L6UL201035
Module [ Site: KIT] versions: M6UL2T3010353B2 |
QR pdf
FEB_A: 3032 FEB_B: 4032 -- Last status: 2026-04-11 13:22 [ Tested on ladder ]
Desired grade: B
History of statuses:
Comments:
- 2026-05-08 13:18 { Kerstin Schuenemann } ( ODI all ok )
- 2026-04-09 14:07 { Carmen Simons } ( tested on ladder with oscilloscope, ODI ok )
- 2026-04-02 11:32 { Lady CollazoSanchez } ( The previous comment has an error regarding polarity. The ASICs corresponding to the n-side actually belong to the p-side and vice versa. )
- 2026-04-02 11:15 { Lady CollazoSanchez } ( ODI issues: n-side: ASIC2_UL0, ASIC4_UL0, ASIC5_UL1, ASIC6_UL1, ASIC7_UL1. p-side: ASIC0_UL0, ASIC1, ASIC2_UL1, ASIC3, ASIC5, ASIC7. )
- 2024-10-24 15:09 { Lady CollazoSanchez } ( Asymmetrical current )
No documents uploaded yet.
⇧ Top
Change Module Status:
Ladder: L6UL201035
Module: M6UL2T3010353B2
Sensor: 06144
Status: Tested on ladder