Link to ladder: L6UR101135
Module [ Site: KIT] versions: M6UR1B4011354B2 |
QR pdf
FEB_A: 3130 FEB_B: 4130 -- Last status: 2026-02-18 07:01 [ Tested Uplinks ]
Desired grade: C
History of statuses:
Comments:
- 2026-03-24 13:59 { Johann Heuser } ( The module is still good. Despite the observations: The current during IV testing raises up to ~ 18 uA at 150 V, exhibiting a plateau. Then a unstable current establishes, lowing from 18 uA to 10 uA in rapid spiking. This was seen previously during module testing, but at higher current (32 uA) and the rapid spiking to lower valies starting only at 200 V. )
- 2026-02-16 11:17 { Kerstin Schuenemann } ( ODI all ok )
- 2025-07-15 18:23 { Lady CollazoSanchez } ( High current ~ 32 uA @ 150V. Current fluctuations from 210 - 250 V. )
Workflow
No documents uploaded yet.
⇧ Top
Change Module Status:
Ladder: L6UR101135
Module: M6UR1B4011354B2
Sensor: 14184
Status: Tested Uplinks