FEB_A: 1223 FEB_B: 2217 -- Last status: 2026-03-16 16:43 [ Undef. status at Hk.Hl. ]
Desired grade: B
History of statuses:
Comments:
- 2026-03-24 14:27 { Oleksandr Suddia } ( ULX FEB "B" ASIC1 UL1 to UL0, FEB "A" ASIC1 UL1 to UL0, ASIC7 UL1 to UL0 )
- 2026-03-16 16:43 { Johann Heuser } ( To be checked in HL after ASIC exchange. Or was this done already? )
- 2026-03-16 13:55 { Oleksandr Suddia } ( ASIC6 was replaced )
- 2026-02-04 11:47 { Anju Sharma } ( ODI failed (uplink 0 (0.8kohms)->HW_ID 0), uplink 0(0.6kohms) -> HW_ID 7, uplink 1 (both lines: 0.5kohms and 2.7kohms)-> HW_ID 7 )
- 2026-02-02 16:41 { Anju Sharma } ( Impedance < 1kOhm )
- 2026-02-02 16:33 { Anju Sharma } ( Retested (impedance corresponding to few capacitors are ~1.6kohm) )
No documents uploaded yet.
⇧ Top
Change Module Status:
Ladder: L8UL601024
Module: M8UL6B0010240A2
Sensor: 17042
Status: Undef. status at Hk.Hl.