Link to ladder: L8UL601024
Module [ Site: GSI] versions: M8UL6B2010242A2 |
QR pdf
FEB_A: 1232 FEB_B: 2225 -- Last status: 2026-03-24 13:18 [ Tested Uplinks ]
Desired grade: C
History of statuses:
Comments:
- 2026-03-24 13:18 { Oleksandr Suddia } ( ULX FEB "B" ASIC0 UL1 to UL0 )
- 2026-03-18 11:55 { Christian Schmidt } ( ULX to be done on HW-ID 1 p or n side to be done! )
- 2026-03-17 13:04 { Anju Sharma } ( During ODI uplink 0 (one line-> 1.6kohms) -> HW_ID 1. But for this module one uplink is required. Hence passed. )
- 2026-03-16 16:46 { Johann Heuser } ( Finding "ODI low": what does that mean? Passed or not? Candidate for ULX. )
- 2026-03-03 15:59 { Uli Frankenfeld } ( ODI low )
- 2026-03-03 11:22 { Christian Schmidt } ( detail on Anjus finding: HW_ID 1, uplink 0, 1.6 kOhm )
- 2026-02-02 16:42 { Anju Sharma } ( Impedance ~ 1.6 kOhm (in CL) )
- 2026-02-02 16:34 { Anju Sharma } ( Retested ( impedance <1kOhm) )
- 2025-03-18 15:58 { Lady CollazoSanchez } ( 28 broken channels )
No documents uploaded yet.
⇧ Top
Change Module Status:
Ladder: L8UL601024
Module: M8UL6B2010242A2
Sensor: 18084
Status: Tested Uplinks