[Top] [Prev] [Next] [Contents] [Index]

CONFUI Messages

CONFUI messages pertain to the Configuration daemon user interface. If you are looking for a message that refers to the CONFUI module but does not appear here, refer to "Messages Common to All Modules".


ALRDYUP, already running
Severity:
Error
Explanation:
The Configuration daemon user interface is already running on this terminal.
User Action:
Use the existing user interface, or shut it down and invoke it again.

BADPASS, wrong password for host host

Severity:
Error
Explanation:
The password that has been entered is incorrect for the specified terminal.
User Action:
Obtain the correct password for the terminal to which you are trying to connect.

CONN, can not create connection to host host

Severity:
Error
Explanation:
The CONFUI module cannot connect to the specified terminal.
User Action:
Make sure that the specified terminal name is correct. Confirm that the specified terminal is operational. If it is, confirm that the terminal is connected to the network and that the network is working.

CONNECT, conflib_connect_type parameter failed

Severity:
Error
Explanation:
The X server has detected an internal error. In this message, type refers to the value type, such as Boolean, floating point integer, string, or table.
User Action:
If you encounter this message, please contact NCD Technical Support.

GET, conflib_get_type parameter failed

Severity:
Warning
Explanation:
The X server does not support the specified configuration parameter, perhaps because the parameter is from a previous version of the X server. In this message, type refers to the value type, such as Boolean, floating point integer, string, or table.
User Action:
If you encounter this message, please contact NCD Technical Support.

LOSTCONN, lost connection to host host

Severity:
Error
Explanation:
The CONFUI module has lost its connection to the specified terminal.
User Action:
Confirm that the specified terminal is running. If it is, confirm that the terminal is connected to the network and that the network is operational.

NOCONN, Not connected to any terminal

Severity:
Error
Explanation:
The X server has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

NOEXT, can not get NCD-SETUP extension

Severity:
Warning
Explanation:
The X server has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

NOFONT, can not create font font

Severity:
Error
Explanation:
The specified font is not available.
User Action:
Use the default font or specify a substitute font.

SET, conflib_set_type parameter failed

Severity:
Error
Explanation:
The X server cannot set the specified parameter to the requested value. In this message, type refers to the value type, such as Boolean, floating point integer, string, or table.
User Action:
Verify that the value requested is the type of value accepted by the parameter.

TEST, conflib_test_type parameter failed

Severity:
Error
Explanation:
The X server cannot set the specified parameter to the requested value. In this message, type refers to the value type, such as Boolean, floating point integer, string, or table.
User Action:
Verify that the value requested is the type of value accepted by the parameter.

XERROR, X_name error, request code n.n, value value

Severity:
Error
Explanation:
An error has occurred in the MIT X server.
User Action:
Refer to Xlib documentation for information on the specified error.


[Top] [Prev] [Next] [Contents] [Index]

Send comments, suggestions, or questions about this document to the NCD Technical Publications Department by Internet e-mail. Write to us at techpubs@ncd.com.
Copyright © 1997, NCD Inc. All rights reserved.