[Top] [Prev] [Next] [Contents] [Index]
CONFUI Messages
CONFUI messages pertain to the Configuration daemon user interface. If you are looking for a message that refers to the CONFUI module but does not appear here, refer to "Messages Common to All Modules".
ALRDYUP, already running
- Severity:
- Error
- Explanation:
- The Configuration daemon user interface is already running on
this terminal.
- User Action:
- Use the existing user interface, or shut it down and invoke it
again.
BADPASS, wrong password for host host
- Severity:
- Error
- Explanation:
- The password that has been entered is incorrect for the specified
terminal.
- User Action:
- Obtain the correct password for the terminal to which you are
trying to connect.
CONN, can not create connection to host host
- Severity:
- Error
- Explanation:
- The CONFUI module cannot connect to the specified terminal.
- User Action:
- Make sure that the specified terminal name is correct. Confirm
that the specified terminal is operational. If it is, confirm that the terminal is
connected to the network and that the network is working.
CONNECT, conflib_connect_type parameter failed
- Severity:
- Error
- Explanation:
- The X server has detected an internal error. In this message, type
refers to the value type, such as Boolean, floating point integer, string, or table.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
GET, conflib_get_type parameter failed
- Severity:
- Warning
- Explanation:
- The X server does not support the specified configuration
parameter, perhaps because the parameter is from a previous version of the X
server. In this message, type refers to the value type, such as Boolean, floating
point integer, string, or table.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
LOSTCONN, lost connection to host host
- Severity:
- Error
- Explanation:
- The CONFUI module has lost its connection to the specified
terminal.
- User Action:
- Confirm that the specified terminal is running. If it is, confirm
that the terminal is connected to the network and that the network is
operational.
NOCONN, Not connected to any terminal
- Severity:
- Error
- Explanation:
- The X server has detected an internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
NOEXT, can not get NCD-SETUP extension
- Severity:
- Warning
- Explanation:
- The X server has detected an internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
NOFONT, can not create font font
- Severity:
- Error
- Explanation:
- The specified font is not available.
- User Action:
- Use the default font or specify a substitute font.
SET, conflib_set_type parameter failed
- Severity:
- Error
- Explanation:
- The X server cannot set the specified parameter to the requested
value. In this message, type refers to the value type, such as Boolean, floating
point integer, string, or table.
- User Action:
- Verify that the value requested is the type of value accepted by
the parameter.
TEST, conflib_test_type parameter failed
- Severity:
- Error
- Explanation:
- The X server cannot set the specified parameter to the requested
value. In this message, type refers to the value type, such as Boolean, floating
point integer, string, or table.
- User Action:
- Verify that the value requested is the type of value accepted by
the parameter.
XERROR, X_name error, request code n.n, value value
- Severity:
- Error
- Explanation:
- An error has occurred in the MIT X server.
- User Action:
- Refer to Xlib documentation for information on the specified
error.
[Top] [Prev] [Next] [Contents] [Index]
Send comments, suggestions, or questions about this document to the NCD Technical Publications Department by Internet e-mail. Write to us at
techpubs@ncd.com.
Copyright © 1997, NCD Inc. All rights
reserved.