The fix bos.rte.control 4.2.1.7 is broken.
Reinstall bos.rte.control.
During the reinstallation, watch for the following errors:
sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/exec_shutdown. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/exec_sh tdown. sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/reboot. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/reboot. sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/shutdown. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/shutdow . sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/exec_shutdown. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/exec_sh tdown. sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/reboot. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/reboot. sysck: 3001-038 The name shutdown is not a known group for entry /usr/sbin/shutdown. sysck: 3001-003 A value must be specified for group for entry /usr/sbin/shutdow . sysck: 3001-017 Errors were detected validating the files for package bos.rte.control. installp: The installation has FAILED for the "usr" part of the following filesets: bos.rte.control 4.2.1.7
If these errors appear, look in /etc/group for a group called shutdown. If there is no such group, modify /etc/group to have the following line:
shutdown:!:21:
Then install the fix.
[ Doc Ref: 93327134513346 Publish Date: Aug. 20, 1999 4FAX Ref: none ]