******************************************************************************* This is the list of runs in 2000. The primary purpose was for daq history. This is why important daq changes are described by a separate line. The information comes from the paper log-book, the paper run-sheets, and the electronic run-comments. The columns are: - run stop date - run nr - total number of bursts - beam intensity * 1e-6 (per burst) - trigger - magnetic field - comments The comments contain information about the changes in the setup which may be relevant to deciding whether the run can be analyzed together with the previous or the subsequent run (natural boundaries). The comments also specify the purpose of non-standard runs. The syntax used in the comments is explained by a couple of examples shown below: - access - zone was open before this run - TPC peds - new TPC peds were taken before this run - RICH volt - RICH voltage was adjusted before this run - RICH volt at 163 - RICH voltage was adjusted around burst 163 - RICH bad from 40 - RICH information useless from burst 40 on D. Miskowiec, August 2001 ******************************************************************************* start of proton beam Sep 6 18 run 1002 43 Sep 7 01 run 1004 9 access, TPC peds Sep 7 07 run 1005 748 Sep 8 05 run 1009 53 TPC peds Sep 8 06 run 1010 89 Sep 8 06 run 1011 8 Sep 8 07 run 1012 4 Sep 8 07 run 1014 31 Sep 8 07 run 1015 9 Sep 8 08 run 1016 25 Sep 8 09 run 1017 9 Sep 9 03 run 1018 16 access, TPC peds Sep 9 04 run 1019 42 bad TPC peds Sep 9 04 run 1020 14 Sep 9 10 run 1021 15 Sep 9 10 run 1022 7 Sep 9 11 run 1023 42 ? peds Sep 9 13 run 1026 22 Sep 9 18 run 1033 51 RICH volt end of proton beam Sep 10 00 run 1034 2 MT Sep 10 00 run 1035 3 MT ? peds Sep 11 23 run 1039 1 laser 6 no TPC Sep 11 23 run 1040 5 laser 7 Sep 11 23 run 1041 5 laser 8 Sep 11 23 run 1042 5 laser 8c Sep 13 22 run 1045 51 laser 7 ? peds Sep 13 23 run 1046 71 laser Sep 14 00 run 1047 30 laser 10 Sep 19 10 run 1048 45 MT rich peds Sep 19 12 run 1049 72 MT all peds Sep 19 16 run 1054 20 MT Sep 19 19 run 1056 34 MT Sep 20 09 run 1063 287 MT first run with complete setup Sep 21 03 run 1068 17 MT Sep 21 03 run 1069 12 MT Sep 21 03 run 1070 18 MT Sep 21 10 run 1071 292 MT Sep 21 10 run 1072 17 MT Sep 21 21 run 1073 3 MT TPC peds Sep 22 11 run 1074 171 MT Sep 22 15 run 1078 87 MT only TPC Sep 22 16 run 1079 18 MT Sep 23 04 run 1080 43 MT Sep 23 04 run 1081 29 MT Sep 23 05 run 1082 23 MT Sep 23 05 run 1083 16 MT start of 80 GeV Sep 24 11 run 1090 40 minb zero no SD Sep 24 13 run 1098 35 minb zero access, no SD Sep 24 13 run 1099 62 minb zero Sep 24 16 run 1104 21 minb +4120? beam det volt at? Sep 24 19 run 1105 238 minb +4120? beam det volt Sep 24 20 run 1106 49 minb +4120? TPC ch0-1 missing from 49 Sep 24 20 run 1111 32 minb +4120? TPC ch0-1 missing Sep 24 21 run 1112 8 minb +4120 access, TPC peds Sep 24 23 run 1114 33 cent +4160 RICH peds Sep 24 23 run 1115 9 cent +4160 SD bad Sep 25 00 run 1116 10 cent +4160 ? peds Sep 25 02 run 1118 271 cent +4160 Sep 25 03 run 1119 206 cent +4160 Sep 25 04 run 1120 93 cent +4160 Sep 25 04 run 1121 55 cent +4160 Sep 25 05 run 1122 156 cent +4160 Sep 25 06 run 1123 129 cent +4160 Sep 25 09 run 1124 363 cent +4160 end of 80 GeV Sep 25 11 run 1132 15 UV zero Sep 25 13 run 1133 342 UV zero RICH peds Sep 25 20 run 1136 25 laser zero Sep 25 20 run 1137 17 laser zero Sep 25 20 run 1138 9 laser zero Sep 25 20 run 1138 9 laser zero Sep 25 21 run 1139 1 laser zero Sep 25 21 run 1140 8 laser zero? Sep 25 22 run 1142 5 MT zero SD test Sep 25 23 run 1143 6 MT zero SD test Sep 26 01 run 1147 12 laser zero Sep 26 01 run 1148 9 laser zero Sep 26 01 run 1149 13 laser zero Sep 26 01 run 1151 11 laser zero Sep 26 01 run 1152 13 laser zero Sep 26 02 run 1153 13 laser zero Sep 26 02 run 1154 23 laser zero start of 160 GeV Sep 26 15 run 1157 8 ? +4160 TPC test Sep 26 15 run 1158 18 ? +4160 TPC test Sep 26 18 run 1160 10 ? +4160 TPC test Sep 26 18 run 1161 11 ? +4160 TPC test Sep 26 18 run 1162 8 ? +4160 TPC test Sep 26 18 run 1163 11 ? +4160 TPC test Sep 26 18 run 1164 13 ? +4160 TPC test Sep 26 18 run 1165 3 minb +4160 TPC test, access, RICH HV Sep 26 19 run 1166 60 UV +4160 Sep 27 00 run 1167 22 beam +4160 TPC peds, RICH volt Sep 27 02 run 1172 8 cent +4160 TPC low ROC gain Sep 27 05 run 1173 291 cent +4160 bad TPC, TPC ROC volt Sep 27 07 run 1174 68 cent +4160 Sep 27 15 run 1177 15 minb +4160 DAQ test Sep 27 15 run 1181 6 cent +4160 Sep 27 19 run 1182 28 cent +4160 Sep 27 20 run 1183 93 cent +4160 beam det volt Sep 27 21 run 1185 133 cent +4160 Sep 28 03 run 1190 247 cent +4160 Sep 28 06 run 1191 124 cent +4160 RICH volt Sep 28 09 run 1192 269 cent +4160 Sep 28 16 run 1195 7 minb +4160 access Sep 28 20 run 1196 23 ? SD fixed Sep 29 01 run 1199 54 cent +4160 peds Sep 29 04 run 1200 ? minb +4160 RICH peds Sep 29 05 run 1201 ? ? +4160 TPC peds Sep 29 06 run 1202 ? ? +4160 RICH peds, TPC peds, RICH volt Sep 29 09 run 1203 ? cent +4160 Sep 29 10 run 1204 ? cent +4160 Sep 29 10 run 1205 69 cent +4160 RICH peds Sep 29 10 run 1207 3 cent +4160 Sep 29 11 run 1208 131 0.4 beam +4160 SD stop-pulse implemented Sep 29 16 run 1211 78 0.4 minb +4160 RICH volt, RICH bad Sep 29 19 run 1212 43 0.5 cent +4160 Sep 29 21 run 1213 374 0.5 cent +4160 Sep 29 23 run 1214 252 0.5 cent +4160 RICH peds Sep 30 01 run 1215 249 0.6 cent +4160 RICH peds Sep 30 02 run 1216 132 0.6 cent +4160 Sep 30 03 run 1218 169 0.6 cent +4160 RICH peds Sep 30 04 run 1219 46 0.6 cent +4160 Sep 30 08 run 1221 438 0.6 cent +4160 RICH peds Sep 30 10 run 1222 214 0.6 cent +4160 RICH peds, RICH volt Sep 30 11 run 1223 184 0.6 cent +4160 SD played with SD 20 dead channels resurected Sep 30 16 run 1226 15 cent +4160 TPC peds Sep 30 17 run 1228 28 0.6 cent +4160 Sep 30 20 run 1229 210 0.7 cent +4160 Sep 30 23 run 1230 430 0.8 cent +4160 RICH volt Sep 30 23 run 1231 30 0.8 cent +4160 TPC mask test Sep 30 23 run 1232 73 cent +4160 Oct 1 03 run 1233 488 0.9 cent +4160 RICH peds, RICH2 low Oct 1 04 run 1234 35 0.0 MT outb +4160 RICH peds Oct 1 07 run 1237 164 0.9- cent +4160 peds Oct 1 09 run 1238 337 0.4 cent +4160 Oct 1 10 run 1239 58 0.4 cent +4160 RICH peds Oct 1 10 run 1240 27 0.4 cent +4160 Oct 1 14 run 1241 599 0.4 cent +4160 Oct 1 14 run 1243 12 0.6 beam +4160 TPC peds, beam displaced 1 mm Oct 1 16 run 1244 174 0.6+ beam +4160 no target, beam 0.6-1.8, RICH peds Oct 1 17 run 1245 17 1.0 beam +4160 old Au target Oct 1 19 run 1248 277 1.0 cent +4160 old Au target Oct 1 21 run 1249 101 0.7 cent +4160 Oct 1 23 run 1250 155 0.4 cent +4160 RICH peds, only 152 good bursts Oct 2 03 run 1251 467 0.4 cent +4160 RICH peds Oct 2 04 run 1253 125 0.4 cent +4160 RICH volt Oct 2 06 run 1254 325 0.4 cent +4160 RICH peds, ended by power cut VME TDC stop timing changed to 55 us Oct 2 10 run 1257 15 cent +4160 RICH peds, SD peds Oct 2 12 run 1258 197 0.6 cent +4160 RICH peds, RICH volt at ? Oct 2 12 run 1259 6 0.6 cent +4160 Oct 2 13 run 1260 62 0.6 cent +4160 Oct 2 15 run 1262 230 0.6 cent +4160 Oct 2 16 run 1263 90 0.6 cent +4160 RICH peds Oct 2 18 run 1264 368 0.6 cent +4160 TPC peds, RICH volt at ? 1.5LT and beam afterprotection: TPC trigger delayed by 1.1 us Oct 2 19 run 1265 49 0.6 cent +4160 TPC bad pedestals Oct 2 20 run 1266 15 0.6 cent +4160 RICH peds, TPC peds Oct 2 20 run 1267 70 0.6 cent*ap +4160 beam afterprotection test, RICH volt Oct 2 21 run 1268 67 0.6 cent*bp +4160 beam beforeprotection test from now on beam before- and afterprotection +- 1 microsecond active by default Oct 2 21 run 1269 4 0.6 cent +4160 Oct 2 21 run 1270 43 0.6 cent +4160 Oct 2 23 run 1271 247 0.6 cent +4160 Oct 3 01 run 1272 266 0.7 cent +4160 TPC peds, RICH volt Oct 3 03 run 1273 314 0.7 cent +4160 RICH peds Oct 3 06 run 1274 363 0.7 cent +4160 RICH peds Oct 3 07 run 1275 81 0.7 cent +4160 RICH peds Oct 3 09 run 1276 329 0.7 cent +4160 Oct 3 09 run 1277 75 0.7 cent +4160 RICH peds Oct 3 10 run 1278 20 0.7 cent +4160 TPC peds Oct 3 12 run 1279 57 cent +4160 RICH peds, centrality study Oct 3 17 run 1280 238 0.7 cent +4160 TPC field cage alarm burst 148-150 Oct 3 18 run 1281 151 0.7 cent +4160 Oct 3 19 run 1282 156 0.7 cent +4160 TPC peds Oct 3 20 run 1283 19 0.7 cent +4160 Oct 3 21 run 1284 71 0.6 cent +4160 RICH peds Oct 3 22 run 1285 44 0.6 cent +4160 higher centrality Oct 4 02 run 1288 52 0.5 cent,MT +4160 TPC peds, RICH peds Oct 4 02 run 1289 65 0.5+ cent,MT +4160 TPC peds, RICH peds Oct 4 04 run 1290 302 0.7 cent,MT +4160 Oct 4 04 run 1291 2 0.6 beam +4160 trigger bit test Oct 4 04 run 1292 2 0.6 minb +4160 trigger bit test Oct 4 04 run 1293 2 0.6 MT inb +4160 trigger bit test Oct 4 05 run 1294 164 0.6 cent,MT +4160 Oct 4 11 run 1295 863 0.5+ cent,MT +4160 last few bursts bad VME TDC0 stop timing changed from 54.8 us to 22.5 us Oct 4 13 run 1297 219 0.7 cent,MT +4160 SD scanner 14, RICH volt at 163 Oct 4 16 run 1298 209 0.5 cent,MT +4160 RICH peds Oct 4 16 run 1299 23 1.0 cent,MT +4160 TPC peds, higher centrality Oct 4 17 run 1300 47 1.0 cent +4160 Oct 4 18 run 1301 57 1.0 cent RICH peds date and time added to event headers Oct 4 21 run 1303 489 1.0 cent VME TDC0 stop timing changed to 12 us Oct 5 03 run 1304 664 1.0 cent,MT +4160 RICH peds Oct 5 04 run 1306 40 1.0 cent,MT +4160 TPC peds, data corrupted? Oct 5 07 run 1307 414 1.0 cent +4160 Oct 5 09 run 1308 302 1.0 cent +4160 Oct 5 11 run 1309 164 0.8 cent +4160 RICH volt Oct 5 15 run 1310 529 0.6 cent +4160 TPC peds VME TDC setup to read only one edge; stop moved to 20 us Oct 5 16 run 1311 147 0.7 cent +4160 modified TPC setup, RICH volt at ? Oct 5 19 run 1312 435 1.0 cent +4160 RICH volt Oct 5 20 run 1313 25 0.9 cent,MT +4160 TPC mask from 13 Oct 6 04 run 1314 1390 0.9 cent,MT +4160 RICH volt TPC clock phase only 75 ns discovery Oct 6 10 run 1315 910 0.9 cent,MT +4160 RICH peds, RICH volt at 793 Oct 6 13 run 1316 539 1.0 cent,MT +4160 Oct 6 20 run 1317 614 0.9 cent,MT +4160 TPC peds Oct 6 22 run 1318 364 0.0 MT,UV +4160 Oct 7 00 run 1319 228 1.0 cent,MT +4160 Oct 7 02 run 1320 250 1.0 cent,MT +4160 Oct 7 03 run 1321 143 1.0 MT,cent +4160 TPC peds, RICH peds Oct 7 10 run 1322 1068 0.9 cent,MT +4160 RICH peds Oct 7 11 run 1323 94 cent,MT +4160 TPC mask; RICH HV busy off Oct 7 12 run 1324 11 laser +4160 TPC mask test Oct 7 12 run 1325 18 cent,MT,laser+ +4160 RICH HV busy off, mirrors in beam, laser 8c inb Oct 7 12 run 1326 48 cent,MT,laser +4160 mirrors moved out, laser to 8e at ? Oct 7 18 run 1327 448 cent,MT,laser+ +4160 laser 8e outb at ? Oct 7 20 run 1328 62 1.0 cent,MT +4160 TPC peds Oct 7 20 run 1329 67 1.0 cent,MT,laser +4160 Oct 8 12 run 1330 2423 1.0 cent,MT,laser +4160 RICH peds, RICH HV temporarily off, RICH volt at 2538,2630? Oct 8 17 run 1331 651 1.0 cent,MT,laser +4160 RICH1 bad bursts 1-156, RICH volt at 290, new TPC mask at 325 Oct 8 18 run 1332 48 1.0 cent +4160 Oct 8 19 run 1333 238 1.0 cent,laser+ +4160 RICH volt Oct 8 23 run 1334 459 0.8+ cent,laser- +4160 RICH peds Oct 9 09 run 1335 1356 1.0 cent,laser- +4160 Oct 9 14 run 1336 503 1.0 cent,MT,laser- +4160 TPC peds Oct 9 18 run 1337 453 1.0 cent,MT,laser+ +4160 access, RICH volt at 50 Oct 9 19 run 1338 13 0.9 cent,MT,laser +4160 DAQ pipeline test Oct 9 19 run 1339 12 0.9 cent +4160 DAQ pipeline test Oct 9 19 run 1340 45 0.8 cent,MT,laser +4160 Oct 9 19 run 1341 9 0.7 cent,MT,laser +4160 DAQ pipeline test Oct 10 01 run 1342 789 0.9 cent,MT,laser+ +4160 TPC ch0 row 1 missing Oct 10 02 run 1343 114 1.0 cent,MT,laser+ +4160 RICH volt Oct 10 05 run 1344 457 1.0 cent,MT,laser+ +4160 TPC peds Oct 10 05 run 1345 14 1.0 cent,MT,laser +4160 TPC clock 2.7 MHZ (200 samples) Oct 10 06 run 1346 3 1.0 cent,MT,laser +4160 TPC clock 2.0 MHZ (150 samples) Oct 10 07 run 1347 67 cent,MT,laser +4160 TPC clock standard, all peds Oct 10 10 run 1348 480 1.0 cent,MT,laser +4160 RICH volt at 167,285,600?, TPC peds Oct 10 11 run 1349 13 1.0 cent,MT,laser +4160 access, RICH volt at 8 Oct 10 14 run 1350 389 1.0 cent,MT,laser +4160 Oct 10 15 run 1351 60 1.0 cent,MT,laser +4160 Oct 10 16 run 1352 9 1.0 cent,MT,laser +4160 access TPC pipeline Oct 10 18 run 1353 266 1.1 cent,MT,laser +4160 Oct 10 20 run 1354 268 1.0 cent,MT,laser +4160 Oct 10 21 run 1355 21 1.0 cent,MT,laser +4160 Oct 10 22 run 1356 259 1.1 cent,MT,laser +4160 RICH peds Oct 11 05 run 1359 421 1.0 cent,MT,laser +4160 TPC peds Oct 11 06 run 1360 102 1.1 cent,MT,laser+ +4160 RICH peds, RICH2 chain missing Oct 11 14 run 1361 1233 1.0 cent,MT,laser +4160 RICH peds, RICH autoramp test after 1223 RICH autoramp Oct 11 15 run 1362 62 1.0 cent,MT +4160 Oct 11 16 run 1363 98 1.0 cent,MT +4160 access, RICH peds Oct 11 17 run 1364 210 1.0 cent,MT,laser +4160 Oct 11 18 run 1365 108 1.0 cent,MT,laser +4160 Oct 11 21 run 1366 343 1.0 cent,MT,laser +4160 Oct 12 02 run 1367 433 1.0 cent,MT,laser +4160 Oct 12 11 run 1368 87 laser +4160 Oct 12 11 run 1369 56 0.0 laser +4160 Oct 12 14 run 1370 389 cent,MT,laser +4160 varying beam Oct 12 15 run 1371 138 1.0 cent,MT,laser +4160 RICH volt at ? Oct 12 15 run 1372 31 1.0 minb,MT,laser +4160 RICH peds Oct 12 16 run 1373 120 1.0 cent,MT,laser +4160 Oct 12 21 run 1374 615 1.0 cent,MT,laser +4160 RICH and SD bad in last bursts, RICH ramping problem Oct 13 03 run 1375 773 1.0 cent,MT,laser +4160 RICH peds, RICH ramping problem Oct 13 05 run 1376 301 1.0 cent,MT,laser +4160 RICH ramping problem Oct 13 06 run 1377 13 1.0 cent,MT,laser +4160 RICH peds, SD and RICH has run nr 1000 Oct 13 09 run 1379 506 1.0 cent,MT,laser +4160 Oct 13 10 run 1380 131 1.0 cent,MT +4160 RICH2 blind - since when? Restored. Oct 13 10 run 1381 9 1.0 cent,MT +4160 water alarm Oct 13 15 run 1382 68 1.0 cent,MT zero TPC no mask, beam det volt, RICH volt Oct 13 17 run 1383 215 1.0 cent,MT zero TPC no mask Oct 13 19 run 1384 303 1.0 cent,MT zero TPC no mask Oct 13 22 run 1385 144 1.0 cent,MT +4160 TPC no mask Oct 13 23 run 1386 60 1.0 cent,MT,laser +4160 RICH2 low Oct 14 03 run 1387 508 1.0 cent,MT,laser +4160 Oct 14 03 run 1388 9 1.0 cent,MT,laser +4160 Oct 14 15 run 1389 1767 1.0 cent,MT,laser +4160 tetris in RICH start Oct 14 17 run 1390 386 1.0 cent,MT,laser +4160 Oct 14 19 run 1392 269 1.0 cent,MT,laser +4160 RICH peds Oct 15 02 run 1393 934 1.0 cent,MT,laser +4160 RICH volt at 344 Oct 15 07 run 1394 906 1.0 cent,MT,laser +4160 Oct 15 11 run 1395 591 1.0 cent,MT,laser +4160 Oct 15 16 run 1396 674 1.0 cent,MT,laser +4160 RICH peds Oct 15 18 run 1397 324 1.0 MT,laser? +4160 RICH peds Oct 15 19 run 1398 20 1.0 MT? +4160 access, RICH bad, RICH peds Oct 15 19 run 1399 87 1.0 cent,MT,laser +4160 Oct 16 14 run 1400 1646 1.0 cent,MT,laser +4160 TPC peds, TPC peds at 610,1011 tetris in RICH end Oct 16 17 run 1401 252 1.0 cent,MT,laser +4160 RICH bad after burst 199 Oct 16 23 run 1403 884 1.0 cent,MT,laser +4160 beam det volt bursts 175-195 Oct 17 00 run 1404 101 1.0 cent,MT,laser +4160 Oct 17 00 run 1405 26 1.0 minb +4160 Oct 17 05 run 1406 627 1.0 cent,MT +4160 SD bad in bursts 531-569 Oct 17 06 run 1407 82 1.0 cent,MT +4160 Oct 17 08 run 1408 397 1.1 cent,MT +4160 Oct 17 12 run 1409 685 1.0 cent,MT +4160 RICH volt Oct 17 15 run 1410 424 1.0 cent,MT +4160 Oct 17 21 run 1411 728 1.0 cent,MT +4160 no beam protection? Oct 17 23 run 1412 98 laser +4160 Oct 18 04 run 1413 629 1.0 cent,MT +4160 Oct 18 08 run 1414 647 cent,MT +4160 RICH peds Oct 18 10 run 1415 81 1.0 beam,MT +4160 Oct 18 11 run 1416 25 1.0 beam,MT +4160 SD peds, SD bad Oct 18 15 run 1419 503 1.0 beam,MT +4160 Oct 18 17 run 1420 174 1.0 minb,MT +4160 Oct 18 17 run 1421 30 1.0 cent +4160 no beam protections Oct 18 17 run 1422 57 1.0 cent,MT +4160 Oct 18 19 run 1423 158 0.2 beam,MT +4160 low beam 150k Oct 18 20 run 1424 202 0.2 minb,MT +4160 low beam 150k, very peripheral Oct 18 20 run 1425 20 1.0 minb->cent +4160 RICH gain test, minb-cent after b9 trigger abort implementation changed Oct 19 01 run 1426 191 1.0 cent,MTout +4160 access, TPC no zerosup Oct 19 01 run 1427 54 1.0 cent +4160 Oct 19 04 run 1428 504 1.0 cent +4160 beam det volt Oct 19 07 run 1429 564 1.0 cent +4160 Oct 19 09 run 1430 348 1.0 cent +4160 Oct 19 09 run 1431 13 0.0 laser +4160 access Oct 19 10 run 1432 9 0.0 laser? +4160 Oct 19 10 run 1433 26 0.0 laser +4160 Oct 19 11 run 1434 202 0.0 laser changing Oct 19 11 run 1435 25 0.0 laser -4160 Oct 19 15 run 1436 437 cent,MT,laser -4160 RICH peds, TPC initialized at 425 Oct 19 19 run 1437 841 1.0 cent,MT -4160 Oct 20 02 run 1438 1196 1.0 cent,MT -4160 RICH volt at 268, RICH peds Oct 20 13 run 1439 1646 1.0 cent,MT -4160 Oct 20 20 run 1440 343 1.1 cent,MT -4160 Oct 20 22 run 1441 288 1.0 cent,MT -4160 Oct 21 00 run 1442 252 1.0 cent,MT -4160 RICH peds Oct 21 16 run 1443 2853 0.9 cent,MT -4160 cent changing; RICH2 chain missing discovered; TPC initialized at 2111 Oct 21 22 run 1444 1104 1.0 cent,MT -4160 ended by B trip, beam det volt Oct 21 23 run 1445 19 1.1 cent,MT -4160 ended by B trip, beam det volt Oct 22 01 run 1446 39 cent,MT zero Oct 22 02 run 1447 18 cent,MT zero ? peds, TPC no mask? Oct 22 04 run 1448 451 cent,MT zero TPC no mask? Oct 22 08 run 1449 545 cent,MT zero Oct 22 16 run 1450 498 cent,MT zero+ access, RICH peds, last bursts with B Oct 22 20 run 1452 633 1.0 cent,MT +4160 Oct 22 20 run 1453 3 cent,MT +4160 RICH peds, B=0 discovered Oct 23 00 run 1454 455 1.0 cent,MT +4160 B trip? Oct 23 15 run 1455 102 1.0 minb,MT zero Oct 23 18 run 1456 534 0.2 minb,MT zero low beam 150k Oct 24 08 run 1457 1567 1.0 cent,MT +4160? access, RICH volt Oct 24 12 run 1459 13 laser zero Oct 24 12 run 1460 10 laser zero no TPC mask start Oct 24 12 run 1461 9 laser zero Oct 24 13 run 1464 4 laser zero Oct 24 13 run 1465 10 laser zero Oct 24 14 run 1466 9 laser zero Oct 24 14 run 1467 8 laser zero Oct 24 14 run 1468 9 laser zero Oct 24 14 run 1469 10 laser zero Oct 24 14 run 1470 9 laser zero Oct 24 14 run 1471 10 laser zero Oct 24 14 run 1472 13 laser changing Oct 24 14 run 1473 12 laser +4160 Oct 24 14 run 1474 10 laser +4160 Oct 24 14 run 1475 9 laser +4160 Oct 24 14 run 1476 18 laser +4160 access Oct 24 18 run 1477 458 0.9 cent,MT +4160 TPC peds, with TPC mask start Oct 24 21 run 1478 167 1.0 cent,MT +4160 centrality 20 Oct 25 00 run 1479 487 1.0 cent,MT +4160 centrality 20->12 at 470 Oct 25 05 run 1480 563 1.0 cent,MT +4160 SD and RICH bad after 500 Oct 25 07 run 1481 374 1.0 cent,MT +4160 Oct 25 10 run 1482 355 1.0 cent,MT +4160 Oct 25 12 run 1484 265 1.0 cent,MT,laser +4160 TPC peds Oct 25 13 run 1485 96 1.2 cent,MT,laser +4160 Oct 25 15 run 1487 135 1.0 cent,MT,laser +4160 Oct 25 17 run 1488 316 1.0 cent,MT,laser +4160 TPC peds Oct 25 18 run 1489 258 1.1 cent,MT,laser +4160 Oct 25 19 run 1490 21 1.0 cent,MT +4160 centrality 12 Oct 25 19 run 1491 20 1.0 cent,MT +4160 centrality 15 Oct 25 19 run 1492 21 1.0 cent,MT +4160 centrality 17 Oct 25 19 run 1493 23 1.0 cent,MT +4160 centrality 20 Oct 25 19 run 1494 30 1.0 cent,MT +4160 centrality 23 Oct 25 19 run 1495 33 1.0 cent,MT +4160 centrality 25 Oct 26 05 run 1496 1707 1.0 cent,MT +4160 Oct 26 06 run 1497 69 1.0 cent,MT +4160 RICH bad from 40 Oct 26 18 run 1498 1438 1.0 cent,MT,laser +4160 RICH fixed Oct 26 21 run 1499 398 1.1 cent,MT,laser +4160 RICH1 no receiver 15 Oct 27 04 run 1500 982 1.0 cent,MT,laser +4160 centrality 15 Oct 27 07 run 1501 290 1.0 cent,MT,laser +4160 centrality 15 Oct 27 09 run 1503 323 1.0 cent,MT,laser +4160 centrality 15 Oct 27 12 run 1504 7 1.0 cent,MT +4160 centrality 15, bad daq Oct 27 13 run 1505 27 1.0 cent,MT +4160 centrality 15, bad daq Oct 27 16 run 1506 563 1.0 cent,MT +4160 centrality 15 Oct 27 17 run 1507 155 1.0 cent,MT +4160 centrality 15 Oct 27 17 run 1508 14 1.0 cent,MT +4160 centrality 15, TPC bad sector, TPC peds Oct 27 21 run 1509 269 1.0 cent,MT +4160 centrality 15, RICH2 bad after b228, TPC peds Oct 27 23 run 1510 170 1.1 cent,MT +4160 centrality 15 Oct 28 04 run 1511 714 1.0 cent,MT +4160 centrality 15 ? peds, RICH volt Oct 28 04 run 1512 44 1.0 cent,MT +4160 centrality 15 Oct 28 10 run 1513 917 1.0 cent,laser +4160 centrality 15, RICH volt at 264,749,755,823 Oct 29 00 run 1514 2292 1.0 cent,MT,laser +4160 centrality 10, RICH volt at 441, TPC peds, SD peds Oct 29 11 run 1515 2073 1.0 cent,MT,laser +4160 Oct 29 16 run 1516 790 1.0 cent,MT,laser +4160 RICH peds, RICH volt at 60, access Oct 29 16 run 1517 140 1.0 minb,MT +4160 Oct 30 02 run 1518 1684 1.0 cent +4160 Oct 30 04 run 1519 198 1.0 cent,MT +4160 centrality 15, RICH2 bad 92-95, RICH volt 32,95, TPC peds Oct 30 07 run 1521 501 1.0 cent,MT +4160 RICH volt at 364 Oct 30 08 run 1522 42 1.0 cent,MT +4160 centrality 15 Oct 30 14 run 1523 1065 1.0 cent,MT +4160 RICH volt at 820 Oct 31 18 run 1524 4611 1.0 cent,MT +4160 RICH peds, SD peds Nov 1 10 run 1525 1684 1.1 cent +4160 RICH volt about 200, at 296 Nov 1 18 run 1527 1261 1.0 cent,MT +4160 Nov 2 07 run 1528 2276 1.1 cent,MT +4160 RICH volt at ? Nov 2 08 run 1529 33 0.1 BC1*3~*MC,MT +4160 Pb+Valve Nov 2 08 run 1530 21 0.1 BC1*3~*MC,MT +4160 Pb+Valve Nov 2 08 run 1531 12 0.1 BC1*2~?,MT +4160 Pb+Valve Nov 2 08 run 1532 23 0.1- BC1*2~ +4160 Pb+Valve Nov 2 08 run 1533 12 0.01 BC1*2~ +4160- Pb+Valve Nov 2 09 run 1534 55 0.01 BC1*2~ zero Pb+Valve Nov 2 12 run 1535 11 laser zero Nov 2 13 run 1536 30 laser zero Nov 2 14 run 1537 25 laser zero Nov 2 14 run 1538 11 laser zero Nov 2 14 run 1539 20 laser zero Nov 2 14 run 1540 14 laser zero Nov 2 14 run 1541 10 Nov 2 14 run 1543 9 Nov 2 14 run 1544 12 laser zero Nov 2 14 run 1545 30 Nov 2 14 run 1546 14 laser zero Nov 2 14 run 1547 10 laser zero Nov 2 15 run 1548 13 laser zero Nov 2 15 run 1549 19 laser zero Nov 2 15 run 1550 9 laser zero Nov 2 15 run 1551 10 laser zero Nov 2 15 run 1552 13 Nov 2 15 run 1553 16 laser +4160 Nov 2 15 run 1554 8 laser +4160 Nov 2 16 run 1555 14 laser +4160 Nov 2 16 run 1556 13 laser +4160 Nov 2 16 run 1559 15 laser +4160 Nov 2 16 run 1560 14 laser +4160 Nov 2 16 run 1561 16 laser +4160 Nov 2 16 run 1562 18 laser +4160 a2ps -1 -f 8 -o nic run-history-2000.txt