prism chamfer

Implementation of the chamfer for the prism. Performance vs. chamfer size.

  • PandaRoot simulations without field
  • configuration with narrow bars, 3 layer spherical lens, and 8 MCPs layout with ~17 mm gap
  • default radii of the lenses ([95,50])
  • pions and kaons @ p = 3.5 GeV/c @ phi = 10.825 deg (for theta scan)
  • time-imaging reconstruction with full-simulated pdfs
  • 10M samples are used for the LUT generations
  • 30k tracks for pdf generation (per each particle species); 5k for determining separation
  • ~2 mrad tracking resolution
  • realistic time precision
  • QE=18(24)% ( black curve). CE=95%
  • spatial QE = 1

Implementation of the chamfer (d) for the prism:

Chamfer definition:

Performance with Time Imaging for polar angle scan @ phi = 10.825 deg:

Performance with Time Imaging for azimuthal angle scans @ theta =30 deg: