[Top] [Prev] [Next] [Contents]  [Index]
 
 SERIALD Messages
SERIALD messages pertain to the terminal's serial port(s) and the Serial daemon. If you are looking for a message that refers to the SERIALD module but that does not appear here, refer to "Messages Common to All Modules".
BADCMD, port: bad cmd hex_value 
- Severity:
- Error
- Explanation:
- The Serial or Parallel daemon has received an invalid serial or 
parallel protocol command.
- User Action:
- Make sure that your host-side print program is properly 
configured to use the serial/parallel protocol.
BADCONFIG, port not enabled for printing
- Severity:
- Error
- Explanation:
- The specified port on the terminal is not configured for 
printing.
- User Action:
- Configure the terminal for printing to the specified port. Make 
sure any host-side requirements are in place.
DNETCLOSE, port: closed session from aa.nnnn
- Severity:
- Information
- Explanation:
- The Serial daemon has closed the serial session with the 
specified DECnet host on the specified serial port.
- User Action:
- None
DNETOPEN, port: opened session from aa.nnnn
- Severity:
- Information
- Explanation:
- The Serial daemon has opened a serial session with the 
specified DECnet host on the specified serial port.
- User Action:
- None
INETCLOSE, port: closed session from nnn.nnn.nnn.nnn
- Severity:
- Information
- Explanation:
- The Serial daemon has closed the serial session with the 
specified IP host on the specified serial port.
- User Action:
- None
INETOPEN, port: opened session from nnn.nnn.nnn.nnn
- Severity:
- Information
- Explanation:
- The Serial daemon has opened a serial session with the 
specified IP host on the specified serial port.
- User Action:
- None
LATCLOSE, port: closed session from host
- Severity:
- Information
- Explanation:
- The Serial daemon has closed a serial session with the specified 
LAT host on the specified serial port.
- User Action:
- None
LATOPEN, port: opened session from host
- Severity:
- Information
- Explanation:
- The Serial daemon has established a serial session with the 
specified LAT host on the specified serial port.
- User Action:
- None
LOSTSTATUS, port: lost status hex_value
- Severity:
- Information
- Explanation:
- The specified port, using the serial protocol, requested status of 
the RS-232 C line. The buffer had no room for this information.
- User Action:
- None
 
[Top] [Prev] [Next] [Contents]  [Index]
Send comments, suggestions, or questions about this document to the NCD Technical Publications Department by Internet e-mail.  Write to us at 
techpubs@ncd.com.
Copyright © 1997, NCD Inc.   All rights
reserved.